79
21. Technical Data
Operating voltage ........................................ Mains voltage input: 115/230 V/AC (switchable), 50/60Hz
Direct voltage input: 11 - 18 V/DC
If the mains voltage input is used, always select the mains voltage at the site of operation first with the
voltage selection switch above the mains socket. If the wrong mains voltage is set, the charger will be
destroyed. Loss of warranty/guarantee!
Never use both inputs at the same time. This may damage the charger. Loss of guarantee/warranty!
Charging/discharging channels ................... 2
Charge current per channel ......................... 0.1 - 12.0 A (depending on the cell number and rechargeable battery
type)
Charging output per channel ....................... 120 W (channel 1 + 2 total: 240 W)
Discharge current per channel .................... 0.1 - 5.0 A (depending on the cell number and rechargeable battery
type)
Discharge output per channel ...................... 10 W max. each (channel 1 + 2 total: 20 W)
Suitable rechargeable batteries ................... NiMH/NiCd, 1 - 15 cells
LiPo/LiIon/LiFe, 1 - 6 cells
Pb, 1 - 10 cells (rated voltage 2 - 20 V)
Discharge current for balancer .................... 500 mA per cell
Delta-U-recognition ...................................... yes (for NiMH/NiCd, adjustable 3 - 15 mV/cell)
Maintenance charge current ........................ yes (for NiMH/NiCd, adjustable 50 - 300 mA, can be switched off)
Safety timer ................................................. yes (10 - 720 minutes, can be switched off)
Rechargeable battery memory .................... 6
Fan integrated ............................................. yes
Ambient conditions ...................................... Temperature 0 °C to +40 °C; humidity 0% to 90% relative, non-
condensing
Weight ......................................................... 1.46 kg
Dimensions .................................................. 180 x 139 x 60 mm (W x D x H)