Error Code 5 - Freezing Cylinder Sensor
The Freezing Cylinder Sensor Error (E5) indicates
a failure of the barrel sensor or if the sensor is out
of range. If the error occurs, contact White Glove
Service for further assistance.
NOTE
When the machine encounters a Freezing Cylinder
Sensor Error, it continues to run using preset timers.
This mode allows the freezing cylinder to continue
making product until it can be serviced.
Error Code 6 - Hopper Sensor
The Hopper Sensor Error (E6) does not occur on
an M202 machine.
Error Code 7 - Drive Motor
If the control panel displays a Drive Motor Error
(E7), the control does not sense the drive motor.
If the error occurs, contact White Glove Service
for further assistance.
Error Code 8 - Cab Sensor
A Cab Sensor Error (E8) does not occur on an
M202 machine.
Error Code 9 - High Pressure Cutout
High Pressure Cutout Errors (E9) are usually
caused by a dirty or inefficient condenser. If the
control panel displays an E9 on an air cooled
machine, check for proper air clearance around
the condenser. In a water cooled machine, check
that the water is not shut off. If the error persists,
contact White Glove Service for further assistance.
Error Code 10 - Auxiliary Sensor
An Auxiliary Temperature Sensor Error (E10) occurs
if the temperature sensor on the control board fails.
If the error occurs, contact White Glove Service
for further assistance.
Error Code 12 - Right Hopper Sensor
The Right Hopper Sensor Error (E12) indicates a
hopper temperature sensor failure. This error also
appears if the sensor is out of range. If the error
occurs, contact White Glove Service for further
assistance.
Error Code 13 - Left Hopper Sensor
The Left Hopper Sensor Error (E13) indicates a
hopper temperature sensor failure. This error also
appears if the sensor is out of range. If the error
occurs, contact White Glove Service for further
assistance.
ALTERNATING FLASHING CONTROL PANEL LIGHTS
The display panel lights flash in an alternating
sequence under any error code. Clear the error
and place the Freezing Cylinder Off/On switch in
the OFF position and back in the ON position.
Содержание Stoelting M202
Страница 1: ...Model M202B OPERATORS MANUAL Manual No 513666 Rev 6 A VOLLRATH DIVISION...
Страница 2: ......
Страница 6: ......
Страница 14: ...Owner s Manual 513666 8 M202B Model Machines...
Страница 28: ...Owner s Manual 513666 20 M202B Model Machines...
Страница 32: ...Owner s Manual 513666 24 M202B Model Machines...