39
Refilling the Sanitizer Tank
For day-to-day operations, use Flo-San®
sanitizer mixed according to the manufacturer’s
instructions in the sanitizer tank. The tank
system delivers solution to specific areas of the
Flavor Burst
®
system such as the Injector Head
and syrup lines during certain
functions. Therefore, check the tank levels on a
daily basis. For proper sanitation, use only
FRESH sanitizer solution in the tank that is no
more than 28 days old. Replace older solution
with fresh sanitizer solution.
1. Disconnect the sanitizer tank from the
sanitizer line.
2. Remove the sanitizer tank’s cap and discard
any remaining Flo-San sanitizer solution.
Rinse out the tank with water.
3. Mix one packet (0.50 oz) of Flo-San® with
two gallons of warm water (108°F / 42°C)
until dissolved. Pour the sanitizer solution
into the tank.
4. Reinstall the cap and tighten sufficiently.
5. Connect the tank to the cabinet using the
sanitizer line.