Modular Induction Dry Well Drop-ins Operator’s Manual
9
TROUBLESHOOTING (CONTINUED)
Display Message
Might be Caused By
Course of Action
Power level or
temperature is flashing.
There is not a pan(s) over the
induction capsule(s).
Place a Vollrath induction-ready steam table pan over the induction capsule(s).
The induction capsule(s) may not be
adjusted to fit the pan.
Set the induction capsule risers to the correct position to match the pan(s). See
“Adjust the Induction Capsules to Accommodate the Pan(s)” on page 3.
The pan is not a Vollrath induction-
ready pan.
Replace the pan with an Vollrath induction-ready pan. For information about
Vollrath induction-ready pans see “Insert Pans of Prepared Hot Food” on page 3.
The induction capsule(s) may be
tilted and therefore preventing
adequate contact with the pan.
Inspect the induction capsule(s). Reposition if one or both are tilted in the well.
BAD PAN
The pan is not a Vollrath induction-
ready pan.
Replace the pan with an Vollrath induction-ready pan. For information about
Vollrath induction-ready pans see “Insert Pans of Prepared Hot Food” on page 3.
The induction capsule(s) may be
tilted and therefore preventing
adequate contact with the pan.
Inspect the induction capsule(s). Reposition if one or both are tilted in the well.
The induction capsule(s) may not be
adjusted to fit the pan.
Adjust the capsule(s) to fit the pan. See “Adjust the Induction Capsules to
Accommodate the Pan(s)” on page 3.
HOT
If the equipment is in use, the pan
may be too hot.
Remove the pan. Allow the pan and equipment to cool before resuming use. Do
not place excessively hot food into the pan. Do not an place an excessively hot pan
into the equipment. Contact Vollrath Technical Services if the problem persists.
F-2
The pan may be too hot.
F-1
The equipment may have overheated.
Relocate the equipment away from external heat sources. Clear any obstructions
to the air intake. Contact Vollrath Technical Services if the problem persists.
F-8
The equipment may have overheated. Specified installation clearances could be violated, reinstall following specified
clearances. Refer to the specification sheet on Vollrath.com.
F-14
Trouble with the electrical
connection.
Make sure the plug is fully inserted into an electrical outlet that matches the rating
on the equipment’s nameplate.
Make sure the electrical circuit is not overloaded.
The supply voltage is incorrect for the
equipment.
Plug the equipment into an outlet with the correct voltage.
—
A USB cable is disconnected or is not
being recognized.
Check the connections on the back of the control to verify the USB cables are
connected. If the problem continues, contact Vollrath Technical Services.
A problem with the control panel.
Contact Vollrath Technical Services.
Other error codes
Internal error.
Contact Vollrath Technical Services.
Содержание FC-6IH-01120
Страница 10: ...10 Modular Induction Dry Well Drop ins Operator s Manual This page intentionally left blank...
Страница 11: ...Modular Induction Dry Well Drop ins Operator s Manual 11 This page intentionally left blank...
Страница 22: ...10 Manuel d utilisation du module encastrable sec induction Page vierge...