3
SECTION 2
TECHNICAL DATA
2.1 Central heating
Synergy 29
Heat input
29.0 kW
Max heat output 60/80
°
C (return & flow temp.)
28.1 kW
Max heat output 30/50
°
C (return & flow temp.)
29.7 kW
Min heat output 60/80
°
C (return & flow temp.)
9.5 kW
Min heat output 30/50
°
C (return & flow temp.)
10.2 kW
Minimum working pressure
0.5 bar
Maximum working pressure
3.0 bar
Minimum flow rate
350 l/h
2.2 Gas pressures
Inlet pressure (G20)
20.0 mbar
Burner pressure maximum
9.3 mbar
Burner pressure minimum
1.25 mbar
Maximum gas rate
3.07 Sm
3
/h
Minimum gas rate
1.05 Sm
3
/h
Injector size (quantity)
14 x 1.35 mm
2.3 Expansion vessel
Capacity
10-litres
Maximum system volume
91-litres
Pre-charge pressure
1.0 bar
2.4 Dimensions
Height
820mm
Width
450mm
Depth
350mm
Dry weight (kg)
47.0
2.5 Clearances
Sides
12mm
Top
150mm from casing or 25mm above flue elbow (whichever is applicable)
Bottom
150mm
Front
600mm
2.6 Connections
Flow & return
22mm
Hot & cold water
15mm
Gas
15mm
Safety valve
15mm
Condense
21mm
2.7 Electrical
Voltage (V/Hz)
230/50
Power consumption
150W
Internal fuse
2A
External fuse
3A
2.8 Flue details (concentric)
Maximum horizontal flue length (60/100mm)
4.90m
Maximum vertical flue length (60/100mm)
5.70m
Maximum horizontal flue length (80/125mm)
11.80m
Maximum vertical flue length (80/125mm)
13.30m
2.8A Flue Details (twin pipes)
Maximum horizontal flue length (80mm + 80mm)
20m+20m
Maximum vertical flue length (80mm + 80mm)
20m+20m
2.9 Efficiency
SEDBUK (%)
87.6