6.16
FLUE FAN (see fig. 27 & 28)
Carry out component removal procedure as
described in 6.4.
Fig. 27: unclip and remove the air chamber cover,
gently pull the cover towards you before lifting
and disengaging (2). Locate and remove the six
screws that secure the front combustion cover,
then remove the cover (3).
Fig. 28: disconnect the electrical connections and
silicone tubes (10) attached to the fan, noting their
positions. Locate and remove the screws (6) that
secure the analogue pressure switch assembly
(4 & 5). Locate and remove the screws that secure
the flue hood and air baffle, disconnect the flue
clip (1) from the fan-flue elbow, and gently ease
the fan (3) & flue hood assembly (2) from its
location. Locate and remove the four screws that
secure the fan to the flue hood. Remove the fan
to flue elbow. Replace in the reverse order. Ensure
all seals are in good condition, taking care to
ensure they are replaced correctly.