![VOKERA Synergy 29 Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/vokera/synergy-29/synergy-29_installation-and-servising-instruction_1044955011.webp)
9
SECTION 4
INSTALLATION
4.1
DELIVERY
Due to the weight of the appliance it may be
necessary for two people to lift and attach the
appliance to its mounting. The appliance is
contained within a heavy-duty cardboard carton.
Lay the carton on the floor with the writing the
correct way up.
4.2
CONTENTS
Contained within the carton is:
●
the boiler
●
the wall bracket
●
template
●
an accessories pack containing appliance
service connections and washers
●
the instruction pack containing the installation
& servicing instructions, user instructions,
Benchmark logbook, guarantee registration
card and a 3-amp fuse.
4.3
UNPACKING (see fig. 6)
At the top of the carton pull both sides open – do
not use a knife – unfold the rest of the carton
from around the appliance, carefully remove all
protective packaging from the appliance and lay
the accessories etc. to one side. Protective gloves
should be used to lift the appliance, the appliance
back-frame should be used for lifting points.
4.4
PREPARATION FOR MOUNTING THE
APPLIANCE (see fig. 6A)
The appliance should be mounted on a smooth,
vertical, non-combustible surface, which must be
capable of supporting the full weight of the
appliance. Care should be exercised when
determining the position of the appliance with
respect to hidden obstructions such as pipes,
cables, etc.
When the position of the appliance has been
decided - using the template supplied – carefully
mark the position of the wall- mounting bracket
(see fig. 6A) and flue-hole (if applicable).
4.5
FITTING THE FLUE
The top flue outlet permits both horizontal and
vertical flue applications to be considered,
alternatively, the Vokera twin flue system can be
utilised if longer flue runs are required.
4.5.1
CONCENTRIC HORIZONTAL FLUE
(For concentric vertical flue, see 4.5.2)
(For twin flue applications, see 4.5.3)
The appliance can be used with either the Vokera
condensing 60/100mm concentric flue system or
the optional 80/125mm concentric flue system.
NOTE
These instructions relate only to the Vokera
condensing 60/100mm concentric flue system.
For specific details on the installation of the 80/
125mm concentric flue system please refer to
the instructions supplied.
The appliance flue outlet elbow can be rotated
through 360
°
on its vertical axis. In addition the
flue may be extended from the outlet elbow in
the horizontal plane (see 2.8). A reduction must
also be made to the maximum length (see table
below) when additional bends are used.
Fig. 6
Fig. 6A
523
115
145
200
820
150
107.5
85
35
453
CONDENSATE
PIPE
RETURN
FLOW
GAS
Содержание Synergy 29
Страница 1: ...Installation Servicing Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER ...
Страница 40: ...38 Fig 45 ...