2N
®
BRI Lite gateway
92
8.6. Records on Calls
Example of a successfully connected call:
**
06.12.05/15:44:57
O-OK
CAU-016
p01/g01
GRP-3
0:18
000:12
00000.00
737111074
112
1/230030102122930
1st column: **
2nd column:
call start date/time
3rd column
: call type
call I-FD : Unconnected incoming call attempt (will be
implemented in a higher firmware version)
I-OK : Successfully connected incoming call (will be
implemented in a higher firmware version)
O-FD : Unconnected outgoing call attempt
O-OK : Successfully connected outgoing
4th column
: CAUSE sent to ISDN
5th column:
used B-channel number / used GSM module
number
6th column
:
used GSM group (C= CallBack)
7th column
:
call establishing time
8th column
: call duration mmm:ss (max. 255:59) or error
cause for unconnected calls
9th column
: call cost (will be implemented in a higher
firmware version)
9th column
: gateway id (optional)
10th column
: called number
11th column:
caller's MSN number
12th column: slot number / used SIM card IMSI or SCID
(Siemens modules only)
VoIPon www.voipon.co.uk [email protected] Tel: +44 (0)1245 808195 Fax: +44 (0)1245 808299