4 Operation
Cross-triggering
Cross-triggering is possible between the VME and P2 analyzers on the VBT-
325, as well as to/from the TIM200-PB 200MHz Timing Analyzer piggyback
module. This is accomplished using the cross-trigger signals VMEtrg, P2trg
and TlMtrg, refer t
▶
.he figure below.
VBT-325
VMEtrg
VMEbus
Analyzer
TI Mtrg
P2trg
VMEtrg
P2 Analyzer
TI M200
200MHz
Analyzer
Figure 28. Cross triggering is possible by means of trigger signals
between the various sub-analyzers.
Example: Cross-trigger VSB from VME
To specify that the P? analyzer (e.g. VSB) should trigger when the VME
analyzer triggers, go to ' Ta r g e t /VSB' , and do ' E d i t /Event
P a t t e r n s ' , insert the cross-trigger signal by typing <INS> or 'AN' and
select VMEtrg from the selection list. Then assign a value to VMEtrg by
typing <CR> and select 'TRIG' . Start both the VME and VSB analyzer at the
same time with
' T r a c e / R u n M u l t i p l e ' .