2 Installation
CPU/host that utilizes hardware handshake (DTR, DSR, RTS, CTS), a
convenient way of retaining this connection is simply to bypass the handshake
signals from the terminal port to the host port through the VBT-325. This can
easily be done by installing jumpers in the N1 and N2 jumper field (N1-1 to
N2-1 etc.), thereby making a one-to-one bypass of the handshake signals
between the terminal and the host. (Note: Since a time delay is introduced
between the two serial ports, this approach is only recommended when the
handshake signals are used in a static manner.)
Power-On
At this point you should have:
• I n s t a l l e d the VBT-325 in a proper slot
• C h e c k e d the power supply
• C o n n e c t e d a terminal (or PC/WS)
Power can now be applied, and after power-up, the front panel display on the
VBT-325 will keep flashing with the text:
19k2 8 1 n
Automatic Baud Rate detection
When the LED display is flashing, the VBT-325 is in the auto baud rate mode,
and is expecting one or more <CR> from the terminal to determine the actual
baud rate. When the baud rate is determined, the start-up menu will be written
to the terminal (see next page).
By default, 8 bits per character, 1 stop bit and no parity is used. This can be
changed by the ' U t i l i t i e s / S e r i a l p o r t s ' command.
19200 baud
recommended
T o get an optimum response time when operating the VBT-325, it is
recommended to set the terminal/PC to 19200 baud.
No response?
If
the display does not show the baud rate after power-up, try to activate the
reset switch on the front panel. If this still does not work, please refer to the
section "FIRMWARE UPGRADE PROCEDURE", and check that the proper
Boot EPROM is installed, that the jumper settings are correct, especially the
jumpers that affects PROM vs. FLASH selection.
20
V
B
T
-
3
2
5
User's Manual
V
M
E
T
R
O
Содержание VBAT-PB
Страница 15: ...x i v 1 1 I 1 1 I I i i I I 1 I I 1 I 1 I I ...
Страница 23: ...1VBT 325 Product overview 8 V B T 3 2 5 User s Manual V M E T R O ...
Страница 125: ...8 Trace examples 110 V B T 3 2 5 User s Manual V M E T R O ...
Страница 144: ...9 VBAT PB VME bus anomaly trigger ITP40 I GND VMETRO V B T 3 2 5 User s Manual 1 2 9 ...
Страница 159: ...1 1Jumper settings 144 V B T 3 2 5 User s Manual V M E T R O ...
Страница 181: ...16 Simulator for PC 166 V B T 3 2 5 User s Manual V M E T R O ...