8
combustible or flammable material and which
are exposed to excessive heat from either the
boiler or the chimney, particularly when
crossing partitions and false ceilings. In these
cases, appropriate thermal insulation should be
used, namely vermiculite.
Check point 16for more information.
Figure 3- Minimum dimensions to respect the envelope and
minimum height of the chimney
The manufacturer will not be responsible for
changes in the properties of the materials
surrounding the boiler and chimney.
Air intake
The heat generated by the boiler results from
the heat produced by the chemical reaction of
combustion of the pellets in the combustion
chamber.
For this combustion to occur under the best
conditions, it is necessary to safeguard the
correct amount of oxidizing agent (oxygen
present in the air).
During operation, the boiler absorbs a quantity
of air from the place where it is located, which
enters the combustion chamber through an air
inlet located at the back of the boiler, which
can be channeled to the outside.
You must not use bends or tubes with a section
smaller than 50mm, nor a maximum length
greater than 800mm.
You must also safeguard that this admission
will never be obstructed from the outside and
that it is at least 20 cm from the ground.
Outside, you should put protection against rain
and wind.
Safeguard the requirements and relating to
ventilation and air supply referred to.
In the figure below you will find several
examples that will help you to verify the
stability and correction of the flame.
Correct combustion
Bright flame with light
yellow color and minimum
amount of pellets in the
brazier
Incorrect combustion
Flame too bright too
much oxidizer.
Too many glowing pellets
come out of the brazier.
Correct the amount of air
(from 0 to +5) correct the
feeder if necessary (from
0 to -5).
If not, contact technical
support.
Incorrect combustion
Flame too dark yellow,
wobbling, with too many
unburned pellets in the
brazier.
Check that the door or
ash bin is closed.
Otherwise, correct the
amount of air (from 0 to
+5) correct the feeder if
necessary (from 0 to -5).
If not, contact technical
support.