35
Note:
For the boiler to work correctly and
safely, both the drawer and the lid must be
properly closed and watertight.
To reassemble everything you just have to
carry out the reverse process.
The processes are repeated for the bottom box.
11.3.1.
Semi-annual cleaning
You must periodically clean the boiler and the
smoke collector or for every 600 kg of pellets
consumed.
This cleaning must also include cleaning the
smoke extraction fan.
Remove the turbulators and clean the tubes with
a steel brush
To access the fume fan, loosen the six screws
that secure the cover to the left side cover.
Loosen the eight screws that secure the lower
rear cover.