background image

®  

 
 
 

ELECTRIC COMBI WALL BOILER 
FOR HEATING AND SANITARY HOT WATER PRODUCTION 
INSTANTANEOUS WITH ACCUMULATION TANK 
Combi 

Ele

k

tra Compact

.. BP-L

 016

 series

 

 

 
 
 
 
 
 
 
 
 
 
 
 

USER AND MAINTENANCE MANUAL 

 

 

 
 
EQUIPMENT CONFORM TO EC DIRECTIVE 2006/95 / EC. And built in compliance with IEC 60335-2-21: 
2012 IEC 60335-1: 2010 EN 60335-2-21: 2003 + A1: 2005 + A2: 2008 - EN 60335-1: 2012 - EN 62233: 2008 

Summary of Contents for Elektra Compact 12 kW BP-L 016

Page 1: ...NSTANTANEOUS WITH ACCUMULATION TANK Combi Elektra Compact BP L 016 series USER AND MAINTENANCE MANUAL EQUIPMENT CONFORM TO EC DIRECTIVE 2006 95 EC And built in compliance with IEC 60335 2 21 2012 IEC 60335 1 2010 EN 60335 2 21 2003 A1 2005 A2 2008 EN 60335 1 2012 EN 62233 2008 ...

Page 2: ...o as to manage both comfort and economy functioning in order to reduce power consumption when the device is not used at the maximum capacity or demand the appliance is fully adjustable both in water temperature of the heating system with the possibility to choice of system at high and low temperature for the underfloor systems and in the domestic hot water temperature The assembly of the component...

Page 3: ...E NETWORK WITH A DISTANCE CONTACT OPENING ALLOWING THE COMPLETE DISCONNECT THE CONDITIONS OF OVERVOLTAGE CATEGORY III UNDER THE RULES OF INSTALLATION IF THE POWER CABLE IS DAMAGED IT MUST BE REPLACED BY THE MANUFACTURER OR THE TECHNICAL ASSISTANCE SERVICE OR OTHERWISE BY A PERSON WITH SIMILAR QUALIFICATION IN ORDER TO PREVENT ANY RISK WATER CAN DRIP FROM EXHAUST DEVICE AGAINST OVERPRESSURE AND THE...

Page 4: ...cal output Elektra Compact 12 kW BP L 016 12 kW maximum electrical output Elektra Compact 18 kW BP L 016 18 kW maximum electrical output Elektra Compact 24 kW BP L 016 24 kW maximum electrical output Appliance dimension Packaging dimensions L Width 660 mm Width 710 mm H Height 875 mm Height 940 mm P Depth 300 mm Depth 390 mm Weight 59 kg Weight 62 5 kg ...

Page 5: ...y water inlet M AC Hot sanitary water output M VSR Heating safety valve 0 3 MPa 3 bar F VSS Sanitary safety valve 0 65 MPa 6 5 bar F The unit is expected to be connected in a continuous manner to the water mains without the use of a set of junctions Bottom view under the boiler It must be removed by opening knock out ...

Page 6: ...he sanitary economy system 0 005 MPa 0 05 bar Maximum limit of thermal safety heating circuit boiler body 100 C Elektra Compact 12 kW BP L 016 12 kW maximum electrical output Single phase electrical supply 230 240 V 50 Hz Weight 59 kg Capacity of tank 37 liters Glass lined steel with inspection flange and magnesium anode Electrical heat power available at heating of 12 kW obtained by n 2 Resistanc...

Page 7: ...y economy system 0 005 MPa 0 05 bar Maximum limit of thermal safety heating circuit boiler body 100 C Elektra Compact 24 kW BP L 016 24 kW maximum electrical output Single phase electrical supply 230 240 V 50 Hz Weight 61 kg Capacity of tank 37 liters Glass lined steel with inspection flange and magnesium anode Electrical heat power available at heating of 24 kW obtained by n 4 Resistance group n ...

Page 8: ...r through the support bracket placed supplied in the box packaging The bracket must be fixed to the wall with five M8 screws with appropriate anchors conform to the type of the wall itself not in the boiler kit The device is attached at the top by bringing the folded portion of the bracket in the chassis through the boiler behind the unit ...

Page 9: ...re for the system is between 1 and 1 5 bar More then 1 5 bar you can have a maximum pressure of the 2 bar maximum expansion of the system during the rise in temperature More than 2 bar pressure the system is not in the range of operation and the mechanical safety valve preset to 3 bar can start to lose water to access the valves remove the knockout openings at the valves see page 2 hydraulic insta...

Page 10: ... press Display temperature output Display setpoint output Unlock error of safety thermostat MODE J4 Summer winter switching long press I J2 Display Increase of heating setpoint or room temperature I J3 Display Decrease of heating setpoint or room temperature H H J5 J6 Enabling function Eco Comfort only if JP8 0 and P8 0 MODE ON OFF J4 J7 Start function degassing J7 J6 J5 J4 J3 J2 ...

Page 11: ...WINTER then When the device will be in WINTER mode on the display will appear the Symbol C snow When the device will be in SUMMER mode on the display will appear the Symbol B sun TEMPERATURE VARIATION OF THE HEATING CIRCUIT When the apparatus has been set with the snow symbol C for the wintry functioning you can change the maximum temperature of heating circuit pressing one of the two keys with th...

Page 12: ...a 0 8 bar by means of the operating and the closure of the charging tap placed under the boiler black handle The display has several symbols signaling in addition to operation modes also the various alarm or system displays Symbol Meaning L Malfunction J Request of burner switch on I Heating request H Sanitary request generic G Function sanitary Comfort activated F Parameter menu activated E Anti ...

Page 13: ...ler resistance 3 6 kW M Hydraulic connection outlet heating circuit RS Sanitary resistance 2 kW rsc Drain valve of boiler body CC Boiler body S Thermowell for immersion sensor rsb Drain valve of tank AF Hydraulic connection inlet sanitary cold water BS Hot water storage tank 37 liters AC Hydraulic connection outlet sanitary hot water SP Brazed heat exchangers For the other models the only changes ...

Page 14: ... 48 47 46 45 44 43 4241 40 38 37 36 55 56 54 J11 Interface 961 O JP7 JP8 JP9 JP10 0 1 39 1 2 3 1 2 3 4 5 6 7 J14 J12 J11 J5 J6 N FT G3 G2 G1 G4 OUT 230 240V 53 OT PE F E PWM whyte yellow red blue brown black black black brown brown blue brown brown blue brown blue red blue white red white brown black DHW CH COM 3 WAY VALVE FLM G5 brown ...

Page 15: ...ntrol Comfort function MS Control gate triac n 1 4 KW power G1 Control gate triac n 2 2 KW power G2 Control gate triac n 3 4 KW power G3 Control gate triac n 4 2 KW power G4 Control gate triac n 5 2 KW sanitary tank G5 Delivery heating probe ntc sensor SM External probe sensor SE Sanitary probe tank SB Water pressure switch PSA Safety thermostat TS Safety thermostat tank TSB Room thermostat termin...

Page 16: ...16 TRIAC Connection scheme ...

Page 17: ...C Room setpoint with external probe present 20 C 10 30 C Tank setpoint 60 C 30 65 C Instantaneous DHW setpoint 50 C 30 60 C PARAMETERS Function Display Def Range External probe start up P 1 0 0 1 Building coefficient of dispersion P 2 35 5 35 C Sanitary post circulation P 3 15 1 180 sec Heating post circulation P 4 30 1 180 sec Heating exchanger circulation starting P 5 0 0 240 sec Min ignition te...

Page 18: ...y The actuaction of each control is reduced to a lapse of 4 seconds Higher is the required power more the control will remain operative in this lapse The power in heating or during a sanitary request is calculated by PID algorithm Please see in the pictures below two examples related to 40 and 60 of total power 12 kW G1 G2 G3 G4 4 s G1 G2 G3 G4 4 s Level power 40 4 8kW Level power 60 7 2kW In case...

Page 19: ... mm and if possible avoiding the insertion along with electric lines digital lines of inverter or other not compatible After the connection the external probe must be enabled by means of the introduction of a variation of P1 parameter changed from 0 to 1 Then the setpoint chased by the heating delivery probe will be calculated as follows Tch C Troom C Text C dc 10 Troom C Tch heating setpoint calc...

Page 20: ...ted independently until the storage tank temperature remains below 70 C In ECO mode is not activated any of the primary exchanger resistance In COMFORT mode simultaneously G1 commands are also controlled G2 G3 G4 relative to the primary exchanger bringing the supply temperature to the boiler setpoint differential set using parameter P7 At the end of the request the circulator remains powered for a...

Page 21: ...is only activated if the primary exchanger temperature is higher than the set temperature using the parameter P6 If the temperature value detected by the primary exchanger probe is lower than the flow temperature setpoint set the triacs are turned on in sequence according to the power required This only occurs after a time set by parameter P5 to allow for example the opening of eventual zone valve...

Page 22: ... Temperature index increase I J3 Temperature index decrease ANTI LOCK CIRCULATOR If the circulator has not performed any operation cycle in a period of time of 24 hours it is activated for 10 seconds in order to avoid long idle block At the end of the post circulation phase activated following a request for domestic hot water the electric diverter valve is powered for 2 seconds to avoid blocking f...

Page 23: ...ment with 12 kW application The first 6 dashes refer to the heating modules of the primary exchanger The dash on the right upper corner refers to the heating module dedicated to the tank G5 only if JP8 0 and JP9 0 G1 G2 G3 G4 G5 Heating request When an heating request occurs the temperature measured by the delivery probe is displayed and the symbol I starts to flash On small digits you see the tan...

Page 24: ...moment it is possible to observe which triac are turned on Temperature display On the small digits will show t followed by the description of the selected temperature while the big digit will show the temperature value Parameters display Will show P followed by the index of the selected parameter and the large value of the parameter Function Display Delivery temperature T h Tank temperature T Dh E...

Page 25: ...OF THE APPARATUS RESET To unlock the device press the ON OFF J7 button which also has the Reset function RESET Code Err Meaning F 9 Hardware EEPROM failure F 1 Insufficient system water pressure F 4 Tank probe error F 3 Boiler delivery probe error F 8 Safety thermostat block To restore press the ON OFF J7 system ...

Page 26: ...latile lock status The communication between the remote control and the electronic board fitted with D E S system can be interrupted in the following ways Interruption of the connection between remote control and board in this case after 1 minute the board starts to work in local mode Noise on communication cable between remote control and board in this case it is possible that remote control and ...

Page 27: ... relay which controls the valve opening area managed by Enchrono HOT SANITARY WATER MODE if only JP8 0 The electric board of Elektra operates in the same way described previously The destre setpoint is set by the user on the remote control Through the Enchrono OT1 OT2 you can enable the ECO COMFORT by pressing P When the ECO function is active the temperature of sanitary and the symbol H is the al...

Page 28: ...on described in Meaning of keys of parameters menu DISPLAY OF MALFUNCTIONS For further details related to remote controls series OT1 OT2 please see the related technical specifications Code Err Meaning F 009 Hardware EEPROM failure F 001 Insufficient system water pressure F 004 Tank probe error F 003 Boiler delivery probe error F 008 Safety thermostat block To restore press the ON OFF J7 system ...

Page 29: ...29 SPARE PARTS 4 Particular Particular Boiler body resistances 32 33 28 40 13 29 30 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 27 26 17 18 19 20 21 25 23 33 24 22 33 ...

Page 30: ...ied both the sheath port probes the sheath door heater and the support flange and inspection Replacing the magnesium anode provides for the disassembly of the group The replacement of the electric resistance does not provide for the emptying of the storage tank because inserted in a sealed sheath in vitrified steel 36 37 38 39 7 34 35 28 32 31 40 41 40 42 40 43 ...

Page 31: ... 12 kW version Cod P 7810 16 Return group Cod P 7614 17 Heating safety valve 0 3 MPa 3 bar Cod P 158 18 Hydrometer Cod P 141 19 Water pressure switch minimum pressure Cod P 7623 20 Delivery group Cod P 7615 21 Inlet tube tank water Cod P 7816 22 Template connection pipes Cod P 7809 23 Outlet tube hot water tank tank dima Cod P 2036 24 Sanitary safety valve 0 65 MPa 6 5 bar Cod P 7540 25 Right side...

Page 32: ... Display Lcd Lcd PCB Cod P 1763 38 Instrument panel of Elektra profil lexan keyboard P 2172 Cod P 7548 39 Lighting general switch on off switch Cod P 1099 40 Flange sheath probe support sheath group for sanitary resistance Cod P 2163 41 Magnesium anode Elektra B BP L Cod P 2165 42 Gasket flange Elektra B BP L tank Cod P 2166 43 Ceramic electric resistance 2 kW for sanitary tank Cod P 2167 32 ...

Page 33: ......

Page 34: ......

Page 35: ... L Landucci n 2 B 51100 PISTOIA ITALY Telefono Telephone 39 0573 532812 Telefax Telefax 39 0573 532890 Tipo di apparecchio Type of equipment Caldaia murale elettrica Electric wall boiler Marchio commerciale Trademark dicitura FIAMMA FIAMMA marked Tipo Modello Type Model Vedi Modello su targhetta dati See the model in data code ELEKTRA 6 12 18 24 ELEKTRA 6 12 18 24 Le norme armonizzate o le specifi...

Page 36: ......

Reviews: