8.
Reconnect the black wire to the heater relay and the white wire to the heating element.
9.
Reconnect the black wiring pair to the fuse holder.
10.
Reconnect the white wiring pair to the main power switch.
11.
Connect the power cord to the wall outlet, but
DO NOT SWITCH ON THE POWER!
After replacing the control board, the firmware must be loaded when the
machine is first powered up. Do not power up the machine until the USB
Flash drive with the proper firmware is connected to the machine.
12.
Follow the procedure for updating the firmware (
see page 67
).