Hardware Pre-Installation Information
530-0267-00 Rev 02
7700 Flash Storage Platform Installation Guide 7.6.3.x
7.6.3
17
7700 Flash Storage Platform Site Information
This section provides site guideline information that describes rack space, power, and cooling
needed to support the 7700 Flash Storage Platform.
Minimum Rack Space
Note:
The minimum 3 RU per device value for FSP shelves in a 7700 FSP storage cluster is also
dependent upon the total number of shelves that are being deployed. Violin Systems recommends
leaving 1 RU above each FSP for service access and other benefits derived from having this
additional rack space available.
Requirements Checklist
Description of Requirements
Violin Symphony VM Requirements
Environment
•
Deploy Symphony VM using VMware vCenter Server 5.0
or later, which is the recommended version (vCenter
Server 4.0 or later is also supported).
•
Symphony VM must be deployed on an ESX/ESXi host
using vCenter Server, and meet the following
requirements:
— ESX/ESXi version 4.1 or later
— 3 GB of RAM
— Minimum available disk space (60 GB for thick LUN
configuration or 4 GB for a thin LUN configuration)
Violin Symphony RPM Requirements
Environment
•
Deploy Symphony RPM as an application bundle running
on your native OS: Red Hat 6.x (64-bit), or CentOS 6.x
(64-bit).
•
Symphony RPM must meet the following requirements:
— 3 GB of RAM
— Minimum available disk space (60 GB for thick LUN
configuration or 4 GB for a thin LUN configuration)
Table 1.3 Violin Systems Symphony Installation Requirements Checklist
Device
RU Per Device
RU Per Cluster
7700 FSP Controller
2
4
Switch
1
2
Shelf
3
--
Table 1.4 Required Rack Unit (RU) Space 7700 Flash Storage Platform
Содержание 7700
Страница 12: ...Preface 6 7700 Flash Storage Platform Installation Guide 7 6 3 x 530 0267 00 Rev 02 ...
Страница 122: ...Appendix A System Reference 116 7700 Series Flash Storage Platform Installation Guide 7 6 3 x 530 0267 00 Rev 02 ...
Страница 144: ...Appendix C Configuring Replication 138 7700 Flash Storage Platform Installation Guide 7 6 3 x 530 0267 00 Rev 02 ...
Страница 180: ...Appendix G Managing HA Using CLI Commands 174 7700 Flash Storage Platform Installation Guide 7 6 3 x 530 0267 00 Rev 02 ...
Страница 195: ...Korea RFI Statement 530 0267 00 Rev 02 7700 Flash Storage Platform Installation Guide 7 6 3 x 189 Korea RFI Statement ...
Страница 202: ...Appendix H Compliance Information 196 7700 Flash Storage Platform Installation Guide 7 6 3 x 530 0267 00 Rev 02 ...
Страница 208: ...202 7700 Flash Storage Platform Installation Guide 7 6 3 x 530 0267 00 Rev 02 ...