Appendix A - System Reference
94
7700 Series Flash Storage Platform Installation Guide 7.6.3.x
530-0267-00 Rev 02
Configuring the 7000 Series FSP
Use the following topics to manually configure Memory Gateways and other important settings on
a new 7000 Series Flash Storage Platform:
•
Configuring the Memory Gateways
•
•
Enabling the Configuration Repositories
•
•
Rescanning all Memory Gateway Devices
•
Setting up High Availability (HA) and Failover
Configuring the Memory Gateways
Complete the steps in this section to configure the Memory Gateways.
Powering on the Memory Gateways
Both Memory Gateways need to be manually powered on to continue with the configuration
process.
1.
Log in to the Master ACM.
2.
Issue the following commands from the Master ACM to reboot
both
Memory Gateways:
Configuring the Network on the Memory Gateways
IMPORTANT
: After the Memory Gateways are powered on, issue the following commands to
eliminate IP conflicts between the Memory Gateways on eth1. The eth1 IP address on Memory
Gateway A and on Memory Gateway B are set to the same IP value by default.
1.
Start a terminal session (using PuTTY or a similar SSH program) to connect to Memory
Gateway A using its hostname or IP address, which was set while completing the
configuration wizard.
2.
Log in to Memory Gateway A:
•
User name:
root
•
Password:
<password>
(config) #
array modules id mg-a enable
(config) #
array modules id mg-b enable
[root@violin-MG-A]# networkconfig.sh initialize
[root@violin-MG-A]# networkconfig.sh setnic eth1 no 1500 1 -1 1.0.0.4
255.255.255.0
[root@violin-MG-A ~]# networkconfig.sh finalize
[root@violin-MG-A ~]# networkconfig.sh restart 1 1 1
Содержание 7700
Страница 12: ...Preface 6 7700 Flash Storage Platform Installation Guide 7 6 3 x 530 0267 00 Rev 02 ...
Страница 122: ...Appendix A System Reference 116 7700 Series Flash Storage Platform Installation Guide 7 6 3 x 530 0267 00 Rev 02 ...
Страница 144: ...Appendix C Configuring Replication 138 7700 Flash Storage Platform Installation Guide 7 6 3 x 530 0267 00 Rev 02 ...
Страница 180: ...Appendix G Managing HA Using CLI Commands 174 7700 Flash Storage Platform Installation Guide 7 6 3 x 530 0267 00 Rev 02 ...
Страница 195: ...Korea RFI Statement 530 0267 00 Rev 02 7700 Flash Storage Platform Installation Guide 7 6 3 x 189 Korea RFI Statement ...
Страница 202: ...Appendix H Compliance Information 196 7700 Flash Storage Platform Installation Guide 7 6 3 x 530 0267 00 Rev 02 ...
Страница 208: ...202 7700 Flash Storage Platform Installation Guide 7 6 3 x 530 0267 00 Rev 02 ...