Appendix F - Configuring Stretched Cluster and Tiebreaker
160
7700 Flash Storage Platform Installation Guide 7.6.3.x
530-0267-00 Rev 02
Sample output:
Modifying a Tiebreaker Configuration
You must modify your Tiebreaker configuration if:
•
The failover type (for example, Mutual Failover) changes in your failover configuration. The
type must match the Tiebreaker configuration or Tiebreaker will stop monitoring.
•
The power control type changes to a non-supported type for the failover pair. Currently only
IPMI and Dell iDRAC are supported.
To modify an existing Tiebreaker configuration, do the following:
1.
Run command
tiebreakersetup
.
2.
Select [M] to modify a failover pair.
3.
Select the appropriate option for the Tiebreaker configuration you wish to modify.
4.
Enter the changed value.
[a]Failover Type: Mutual Failover
[b]Heartbeat IP address of the first active server: 10.6.13.151
[c]Host name of the first active server: IPS-26950-150
[d]Administration account of the first active server: root
[e]Administration account password of the first active server: *
[f]Heartbeat IP address of the second server: 10.6.13.153
[g]Host name of the second server: IPS-26949-152
[h]Administration account of the second server: root
[i]Administration account password of the second server: *
[j]IP address of the SNMP managers to receive traps: 10.6.3.199
[k]SCI Latency Threshold (ms): 200
[l]Mirror Latency Threshold (ms): 200
[m]Send an SNMP heartbeat trap to monitor the Tiebreaker SNMP daemon: yes
Interval for SNMP heartbeat trap (in seconds): 300
[n]Start monitoring the failover pair: yes
[o]In a split-brain scenario, activate the policy to force a node to
take over its partner when all communications from Tiebreaker to that
partner node have failed: yes
[q]Quit
Содержание 7700
Страница 12: ...Preface 6 7700 Flash Storage Platform Installation Guide 7 6 3 x 530 0267 00 Rev 02 ...
Страница 122: ...Appendix A System Reference 116 7700 Series Flash Storage Platform Installation Guide 7 6 3 x 530 0267 00 Rev 02 ...
Страница 144: ...Appendix C Configuring Replication 138 7700 Flash Storage Platform Installation Guide 7 6 3 x 530 0267 00 Rev 02 ...
Страница 180: ...Appendix G Managing HA Using CLI Commands 174 7700 Flash Storage Platform Installation Guide 7 6 3 x 530 0267 00 Rev 02 ...
Страница 195: ...Korea RFI Statement 530 0267 00 Rev 02 7700 Flash Storage Platform Installation Guide 7 6 3 x 189 Korea RFI Statement ...
Страница 202: ...Appendix H Compliance Information 196 7700 Flash Storage Platform Installation Guide 7 6 3 x 530 0267 00 Rev 02 ...
Страница 208: ...202 7700 Flash Storage Platform Installation Guide 7 6 3 x 530 0267 00 Rev 02 ...