Appendix B - Overview: 7700 FSP Controller
124
7700 Flash Storage Platform Installation Guide 7.6.3.x
530-0267-00 Rev 02
4.
In the
Alerts
page, click
SNMP and Email Settings
, and navigate to the
SMTP (E-mail)
Server Address Settings
pane.
5.
In
SMTP (Email) Server IP Address or FQDN/DNS Name
, enter a valid Fully Qualified
Domain Name hostname or IP address of the SMTP (E-mail) Server, and click
Apply
.
6.
Navigate to the
Destination Email Addresses
pane, and perform the following:
•
Enter a recipient e-mail address in
Destination Email Address
.
•
Select the
State
check box to activate this e-mail address and click
Apply
.
•
Click
Send
and confirm that the designated recipient received an e-mail alert message.
7.
In the
Alerts
page, click
Alert Recurrence
, and in the
Customize Alert Recurrence
pane,
set interval values (in days) for repeating alerts in
Recurrence
for Severity Warning and
Critical events, and click
Apply
.
Note:
It is recommended that you enter a
1
(in the Days field) under the Recurrence column
for Severity Critical events.
8.
In the
Alerts
page, click
Alerts
tab, and in the
Alerts Filter
pane, make sure that all of the
Category and Severity check boxes are selected, and click
Apply
.
9.
In the
Alerts and Remote System Log Configuration
pane, click the
check box in the
column head to select e-mail notifications for all categories of System Health alerts (or select
the individual
check box for those alerts for which you want e-mail notifications).
10.
Click the right-arrow page control (adjacent to
Apply
button) to complete the selection of
check boxes, and click
Apply
.
Содержание 7700
Страница 12: ...Preface 6 7700 Flash Storage Platform Installation Guide 7 6 3 x 530 0267 00 Rev 02 ...
Страница 122: ...Appendix A System Reference 116 7700 Series Flash Storage Platform Installation Guide 7 6 3 x 530 0267 00 Rev 02 ...
Страница 144: ...Appendix C Configuring Replication 138 7700 Flash Storage Platform Installation Guide 7 6 3 x 530 0267 00 Rev 02 ...
Страница 180: ...Appendix G Managing HA Using CLI Commands 174 7700 Flash Storage Platform Installation Guide 7 6 3 x 530 0267 00 Rev 02 ...
Страница 195: ...Korea RFI Statement 530 0267 00 Rev 02 7700 Flash Storage Platform Installation Guide 7 6 3 x 189 Korea RFI Statement ...
Страница 202: ...Appendix H Compliance Information 196 7700 Flash Storage Platform Installation Guide 7 6 3 x 530 0267 00 Rev 02 ...
Страница 208: ...202 7700 Flash Storage Platform Installation Guide 7 6 3 x 530 0267 00 Rev 02 ...