Monitoring 7700 FSP Controllers Using iDRAC
530-0267-00 Rev 02
7700 Flash Storage Platform Installation Guide 7.6.3.x
123
Setting Up DNS and Domain Names in iDRAC
Most alert functions require proper DNS and domain name settings to correctly resolve names to
network IP addresses, and to allow alerts to be correctly formatted for Enterprise hosts. Set up DNS
and domain names in iDRAC by completing the following steps:
1.
Open an HTTPS session using the IP address assigned to the iDRAC interface.
2.
Log in to iDRAC using its login credentials (default login credentials are
admin
and
violin101
).
3.
In the navigation pane, click
Overview > iDRAC Settings > Network
and scroll down to the
Common Settings
pane.
4.
In
Static DNS Domain Name
, enter a valid DNS domain name.
5.
Navigate to the
IPv4 Settings
pane, and in
Static Preferred DNS Server
and
Static
Alternate DNS Server
, enter valid IP addresses.
6.
At the bottom of the
Network
page, click
Apply
to apply all these DNS and domain name
settings.
Setting Up Time Zones and NTP in iDRAC
You should inspect and verify that the time zone and NTP information used by IPMI matches that
information used by other 7700 FSP storage cluster devices.
Set up time zone and NTP information in iDRAC by completing the following:
1.
Open an HTTPS session using the IP address assigned to the iDRAC interface.
2.
Log in to iDRAC using its login credentials (default login credentials are
admin
and
violin101
).
3.
In the navigation pane, click
Overview > iDRAC Settings
and in the
iDRAC Information
page, click
Settings
.
4.
In the
Time Zone and NTP
page, verify the
Time Zone Value
and the
NTP Server 1-2-3
and
Enable Network Time Protocol (NTP
) check box values in the
Time Zone
pane.
5.
Click
Apply
if you make any changes.
Setting Up SNMP E-mail Alerts in iDRAC
iDRAC provides a means to receive SMTP e-mail platform-based alerts about the 7700 FSP
Controllers in the 7700 FSP storage cluster. Use iDRAC to set these e-mail alerts up in addition to
other existing monitoring methods or if you have no other monitoring methods available. To
configure SNMP e-mail alerts in iDRAC, complete the following:
1.
Open an HTTPS session using the IP address assigned to the iDRAC interface.
2.
Log in to iDRAC using its login credentials (default login credentials are
admin
and
violin101
).
3.
In the navigation pane, click
Overview > Server > Alerts
, and in the
Alerts
page navigate to
the
Alerts
pane, click
Enabled
, and click
Apply
.
Содержание 7700
Страница 12: ...Preface 6 7700 Flash Storage Platform Installation Guide 7 6 3 x 530 0267 00 Rev 02 ...
Страница 122: ...Appendix A System Reference 116 7700 Series Flash Storage Platform Installation Guide 7 6 3 x 530 0267 00 Rev 02 ...
Страница 144: ...Appendix C Configuring Replication 138 7700 Flash Storage Platform Installation Guide 7 6 3 x 530 0267 00 Rev 02 ...
Страница 180: ...Appendix G Managing HA Using CLI Commands 174 7700 Flash Storage Platform Installation Guide 7 6 3 x 530 0267 00 Rev 02 ...
Страница 195: ...Korea RFI Statement 530 0267 00 Rev 02 7700 Flash Storage Platform Installation Guide 7 6 3 x 189 Korea RFI Statement ...
Страница 202: ...Appendix H Compliance Information 196 7700 Flash Storage Platform Installation Guide 7 6 3 x 530 0267 00 Rev 02 ...
Страница 208: ...202 7700 Flash Storage Platform Installation Guide 7 6 3 x 530 0267 00 Rev 02 ...