Appendix F - Configuring Stretched Cluster and Tiebreaker
156
7700 Flash Storage Platform Installation Guide 7.6.3.x
530-0267-00 Rev 02
(Set this option if you have chosen to monitor the Tiebreaker SNMP daemon status. This setting
means an SNMP trap will be sent every
n
seconds.)
(Answer
yes
to have Tiebreaker monitor this failover pair.)
(Answer
yes
to allow Tiebreaker to decide what happens when a split-brain event is
encountered.)
Your saved configuration appears below:
4.
Press Enter to continue.
Start monitoring the Tiebreaker pair (y/n), default y : y
In a split-brain scenario, activate the policy to force a node to take
over its partner when all communications from tiebreaker to that partner
node have failed (y/n), default y : y
Do you want to Save (y/n) ? Choose
y
to save.
Failover Type: Non-Mutual Failover
Heartbeat IP address of the first active server: 172.22.12.123
Host name of the first active server: H12-122
Administration account of the first active server: root
IP address of the second server: 172.22.12.132
Host name of the second server: H12-132
Administration account of the second server: root
IP address of the SNMP managers to receive traps: 172.22.12.199
SCI Latency Threshold (ms): 200
Mirror Latency Threshold (ms): 200
Send an SNMP heartbeat trap to monitor the Tiebreaker SNMP daemon: no
Start monitoring the failover pair: yes
In a split-brain scenario, activate the policy to force a node to take
over its partner when all communications from Tiebreaker to that partner
node have failed: yes
Saving Tiebreaker configuration...
The configuration was saved.
Press any key to continue.
Select an action :
a) - [A]dd a failover pair
m) - [M]odify a failover pair
r) - [R]emove a failover pair
q) - [Q]uit
Содержание 7700
Страница 12: ...Preface 6 7700 Flash Storage Platform Installation Guide 7 6 3 x 530 0267 00 Rev 02 ...
Страница 122: ...Appendix A System Reference 116 7700 Series Flash Storage Platform Installation Guide 7 6 3 x 530 0267 00 Rev 02 ...
Страница 144: ...Appendix C Configuring Replication 138 7700 Flash Storage Platform Installation Guide 7 6 3 x 530 0267 00 Rev 02 ...
Страница 180: ...Appendix G Managing HA Using CLI Commands 174 7700 Flash Storage Platform Installation Guide 7 6 3 x 530 0267 00 Rev 02 ...
Страница 195: ...Korea RFI Statement 530 0267 00 Rev 02 7700 Flash Storage Platform Installation Guide 7 6 3 x 189 Korea RFI Statement ...
Страница 202: ...Appendix H Compliance Information 196 7700 Flash Storage Platform Installation Guide 7 6 3 x 530 0267 00 Rev 02 ...
Страница 208: ...202 7700 Flash Storage Platform Installation Guide 7 6 3 x 530 0267 00 Rev 02 ...