Appendix C - Configuring Replication
132
7700 Flash Storage Platform Installation Guide 7.6.3.x
530-0267-00 Rev 02
Verify the file content:
For example:
7.
Perform a network inspection, and confirm the IP address, subnet, and the Concerto setup, as
shown:
8.
Use
iperf -h
to display command parameters related to basic network performance as
shown:
9.
Verify that there is bidirectional bandwidth, going from the local host to the remote host, which
defaults to the destination TCP port 5001 and 1640 (use
-p
to specify alternate ports):
10.
Inspect or edit the HA configuration before attempting to re-enable HA and type '
n
' or
<ctrl>+C
to make no changes to the current
ha_precfg.ini
file, as shown:
Note:
You may wish to add the
rep0
port to the HA configuration (for details, see
on page 135). 7700 FSP Controller A requires both the heartbeat and
monitor IP addresses to be in the same subnet as
rep0
(7700 FSP Controller B also requires
two IP addresses in the same subnet). Complete all
rep0
port configuration prior to issuing the
enableha
command.
11.
Re-enable HA, by issuing the following commands:
12.
Inspect HA, by issuing the following commands:
<site2-rep-network>/<site1-rep-netmask> via <site2-rep-gateway> dev
rep0
#static route added for rep0
192.168.1.8/29 via 192.168.2.9 dev rep0
[controller-a ~]# ifconfig -a | grep rep0 -A8
[controller-a ~]# cat $IS_CONF | grep rep0
[controller-a ~]# iperf -c <site1-rep0-ipaddress>
[controller-a ~]# iperf -h
[mg-a ~]# iperf -c <site1-rep0-ipaddress> –r
[controller-a ~]# cfghaprecfg.sh
[controller-a ~]# isscli enableha -s <site2-cont-a-ipaddress> -u root -
p <password> -S <site2-cont-b-ipaddress> -U root -P <password> -pcu
admin -pcp admin -ar -X 60
[controller-a ~]# sms
[controller-a ~]# isscli getfailoverstatus
Содержание 7700
Страница 12: ...Preface 6 7700 Flash Storage Platform Installation Guide 7 6 3 x 530 0267 00 Rev 02 ...
Страница 122: ...Appendix A System Reference 116 7700 Series Flash Storage Platform Installation Guide 7 6 3 x 530 0267 00 Rev 02 ...
Страница 144: ...Appendix C Configuring Replication 138 7700 Flash Storage Platform Installation Guide 7 6 3 x 530 0267 00 Rev 02 ...
Страница 180: ...Appendix G Managing HA Using CLI Commands 174 7700 Flash Storage Platform Installation Guide 7 6 3 x 530 0267 00 Rev 02 ...
Страница 195: ...Korea RFI Statement 530 0267 00 Rev 02 7700 Flash Storage Platform Installation Guide 7 6 3 x 189 Korea RFI Statement ...
Страница 202: ...Appendix H Compliance Information 196 7700 Flash Storage Platform Installation Guide 7 6 3 x 530 0267 00 Rev 02 ...
Страница 208: ...202 7700 Flash Storage Platform Installation Guide 7 6 3 x 530 0267 00 Rev 02 ...