16
TO ENTER:
Provided there be a vehicle on the Entry magnetic loop (see scheme
4), opening can be controlled by pressing OPEN1, K BUTT or RADIO
switch (OPEN1 performs the boom arm opening only if the TLC,
connected to the Entry Magnetic Loop, contact is closed).
TO EXIT:
Provided there be a vehicle on the Exit magnetic loop (see scheme 4),
opening can be controlled by pressing OPEN2, K BUTT, RADIO switch.
The OPEN2 can be connected to the Exit magnetic loop.
If the DIP8 is turned ON, the OPEN2 will perform the barrier opening
regardless the presence of a vehicle at the Entry.
If the DIP8 is turned OFF, the OPEN2 will perform the barrier opening if
there is no vehicle on the magnetic sensor connected to the TLC input
(TLC contact opened).
In both the conditions, TO ENTER and TO EXIT, from the complete
boom arm open position:
If the Automatic Closing is enabled (DIP3 ON), the boom arm will
close at the end of the delay time programmed (see Point D).
If the Automatic Closing is disabled, the boom arm will remain open
until a closing command is pressed or until the vehicle passes in front
of the photocells, giving an OK CLOSE impulse to the control board
(the OK CLOSE command can be connected to the NO contact of the
photocell receiver).
OPEN2 BUTTON (COM - OPEN2) (ONLY PARK MODE)
If the NORMAL MODE is enabled (DIP6 OFF), the OPEN2
command will be disabled.
If the PARK MODE is enabled (DIP6 ON), the OPEN2 will perform
the boom arm opening depending on the switch DIP8 position.
If DIP8 is turned ON and PARK MODE is enabled, OPEN2 will
perform the boom arm opening regardless the state of the TLC input.
If DIP8 is turned OFF and PARK MODE is enabled, OPEN2 will
perform the boom arm opening only if the TLC contact is OPEN (no
vehicle at the Entry, see scheme 4).
OKCLOSE INPUT (COM - OKCLOSE) (ONLY PARK MODE)
If the NORMAL MODE is enabled (DIP6 OFF), the OKCLOSE
command will be disabled.
If the PARK MODE is enabled (DIP6 ON), the OKCLOSE will
perform the boom arm closure after the vehicle transit.
Usually, this command is connected to the Normally Open contact
from a photocell receiver or a magnetic sensor device installed along
the boom arm closing line. The vehicle will engage the contact when
it reaches the closing line. The boom arm will close as soon as the
vehicle left the closing line and the contact is released.
TRAFFIC LIGHT CONTROL (COM - TLC) (ONLY PARK MODE)
The TLC input can be connected to the Entry magnetic loop device
(see scheme 4). The OPEN1 command is enabled only if the TLC input
is closed, presence of a vehicle at the entrance. Whereas the OPEN2
command is enabled only if the TLC input is opened, absence of a
vehicle at the entrance.
If in PARK MODE the TLC input is useless.
RESTORING OPERATIONS AFTER A BLACKOUT
In case of a blackout occurs, the switch DIP10 permits to change the
barrier behaviour when the mains will be restored.
DIP10 - OFF =>
When the mains is restored, the boom arm will
remains still waiting for a command.
DIP10 - ON =>
When the mains is restored, the boom arm will close.
OPERATING IN PARK MODE (DIP6 ON)
NO
NC
D+
D-
+
D-
S
D+
+
S
COM
+
_
+
_
-
+
4
K BUTTON
STOP
CLOSE
OPEN 1
AERIAL
LED
BUZZER
COAX
PARK OPERATION
DIP 6 ON
MAGNETIC LOOP
TO EXIT
MAGNETIC LOOP
TO ENTRY
R=2K2
12 Vdc max 0,5A for ACCESSORY SUPPLY
12 Vdc max 0,5A for AUTOTEST EDGE
EN