40
and
230V~ Equipment
This equipment allows for the spas to operate only on a 230V~/50
Hz electrical service.
Permanently-Connected 230V~/50Hz, 32A spas require an
RCD protected, 230V~50Hz, 32A Single-Service, or 16A Single
Service, or 16A-16A x2, 400V~,3N, 50Hz, 16Ax3, dedicated
electrical circuit. It is important that this circuit is dedicated (not
being used by any other electrical appliance)
or the spa may not function properly. For specific conversion
instruction, please refer to the system wiring diagram inside
the Control System Box (located in the spa’s equipment
compartment). Installation must be in accordance with all
national and local wiring rules.
Connecting the electrical
service to the spa
IMPORTANT:
Installation must be in accordance with
all national and local wiring rules and performed by a licensed
Electrician.
Step 1:
Choose one of the three available conduit entry points.
(Yellow Black decal)
Step 2:
Determine the conduit diameter and drill a hole that
is properly sized for the conduit (¾” conduit drill 1-1/8” hole, 1”
conduit drill 1-3/8” hole). Use the + as the locator for the center
of the hole. The hole saw must go through two layers of plastic.
There is a 1” space between both layers.
Step 3:
Push the conduit through the hole until it comes out
into the equipment area.
Step 4:
Remove the faceplate to the Control System Box
Step 5:
Connect the conduit to the Control System Box using a
Liquid Tight Connector.
Step 6:
Run the required wires through the conduit to the
Control System Box.
Step 7:
Connect the electrical service wires to the terminal
block located in the Control System Box.
Step 8:
Replace the Control System Box faceplate and the
equipment compartment door. The electrical hook-up is complete.
Note:
To conform with electrical codes, and to create a barrier
against pests, any holes created in the base of your Villeroy &
Boch Spa should be fitted with an appropriate connector.
2016 V&B Owners Manual.indd 40
3/3/2016 1:46:52 PM