© 2011 Viking Preferred Service 

Professional Series Outdoor Gas Grill Warranty

One Year Full Warranty

Outdoor gas grills and all of their component parts, except as detailed below*, are warranted to be free from 
defective materials or workmanship in normal household use for a period of twelve (12) months from the date of 
original retail purchase. Viking Range Corporation, warrantor, agrees to repair or replace, at its option, any part which 
fails or is found to be defective during the warranty period.

*Painted and decorative items are warranted to be free from defective materials or workmanship for a period of 
ninety (90) days from the date of original retail purchase. ANY DEFECTS MUST BE REPORTED TO THE SELLING 
DEALER WITHIN NINETY (90) DAYS FROM DATE OF ORIGINAL RETAIL PURCHASE. Viking Range Corporation 
uses the most up-to-date processes and best materials available to produce all color finishes. However, slight 
color variation may be noticed because of the inherent differences in painted parts and porcelain parts as well as 
differences in kitchen lighting, product locations, and other factors.

Five Year Limited Warranty

Any burner assemblies, TruSear™ infrared burner, infrared rotisserie burner, or porcelain grill grate which fails due to 
defective materials or workmanship in normal household use during the second through fifth year from the date of 
original retail purchase will be repaired or replaced, free of charge for the part itself, with the owner paying all other 
costs, including labor. Corrosion, scratching, and discoloration due to improper use and care of the outdoor product 
is excluded from this warranty.

Lifetime Limited Warranty

Any stainless steel part or porcelain grill grate which rusts through due to defective materials or workmanship in 
normal household use during the fifth through the useful lifetime of the grill from the date of original retail purchase 
will be repaired or replaced, free of charge for the part itself, with the owner paying all other costs, including labor.

Ninety (90) Day Residential Plus Warranty 

This warranty applies to applications where use of the product extends beyond normal residential use. Examples 
are, but not limited to, bed and breakfasts, fire stations, private clubs, churches, etc. This warranty excludes all 
commercial locations such as restaurants, food service locations and institutional food service locations.

This warranty extends to the original purchaser of the product warranted hereunder and to each transferee owner of 
the product during the term of the warranty.

This warranty shall apply to products purchased and located in the United States and Canada. Products must be 
purchased in the country where service is requested. Warranty labor shall be performed by an authorized Viking 
Range Corporation service agency or representative. Warranty shall not apply to damage resulting from abuse, 
accident, natural disaster, loss of electrical power to the product for any reason, alteration, outdoor use, improper 
installation, improper operation, or repair or service of the product by anyone other than an authorized Viking Range 
Corporation service agency or representative. This warranty does not apply to commercial usage. Warrantor is not 
responsible for consequential or incidental damage whether arising out of breach of warranty, breach of contract, or 
otherwise. Some jurisdictions do not allow the exclusion or limitation of incidental of consequential damages, so the 
above limitation or exclusion may not apply to you.

Owner shall be responsible for proper installation, providing normal care and maintenance, providing proof of 
purchase upon request, and making the appliance reasonably accessible for service. If the product or one of its 
component parts contains a defect or malfunction during the warranty period, after a reasonable number of attempts 
by the warrantor to remedy the defects or malfunctions, the owner is entitled to either a refund or replacement of 
the product or its component part or parts. Warrantor’s liability on any claim of any kind, with respect to the goods 
or services covered hereunder, shall in no case exceed the price of the goods or service or part thereof which gives 
rise to the claim.

VIKING RANGE CORPORATION

111 Front Street, Greenwood, Mississippi (MS) 38930 USA 

662-455-1200

For more product information, call 1-888-VIKING1 (845-4641), or visit our  

web site at 

http://www.vikingrange.com

Warranty Information

Содержание VGBQ300-2RE2

Страница 1: ...U LPSURSHU VHUYLFH SURFHGXUHV GRQH E DQ XQTXDOL HG SHUVRQ 3UHIHUUHG 6HUYLFH 7KLV DVH 0DQXDO FRYHUV JHQHUDO DQG VSHFL F LQIRUPDWLRQ LQFOXGLQJ EXW QRW OLPLWHG WR WKH IROORZLQJ PRGHOV VGBQ300 2RE2 VGBQ41...

Страница 2: ...2 Lighting Infrared Rotisserie Burner 12 Before You Begin 12 Canopy Thermometers If Applicable 13 Smoker Burner and Smoker Box 13 Wood Chip Use in Smoker Box 13 Rotisserie 13 SERVICE DIAGNOSTICS AND P...

Страница 3: ...safety messages will be preceded by a safety alert symbol and the word DANGER WARNING or CAUTION These words mean All safety messages will identify the hazard tell you how to reduce the chance of inju...

Страница 4: ...duct extends beyond normal residential use Examples are but not limited to bed and breakfasts re stations private clubs churches etc This warranty excludes all commercial locations such as restaurants...

Страница 5: ...establish warranty period The return of the Owner Registration Card is not a condition of warranty coverage You should however return the Owner Registration Card so that Viking Range Corporation can c...

Страница 6: ...120 VAC 60HZ 2 61 0 cm power cord supply cord with 3 prong grounded plug attached to rotisserie motor Grill burner rating 29 000 BTU Nat 28 000 BTU LP 7 3 kW Nat 6 5 kW LP TruSear burner rating If ap...

Страница 7: ...unded plug attached to grill 120 VAC 60HZ 2 61 0 cm power cord supply cord with 3 prong grounded plug attached to rotisserie motor Grill burner rating 29 000 BTU Nat 28 000 BTU LP 7 3 kW Nat 6 5 kW LP...

Страница 8: ...s Goods Gas Manifold Pressure Natural gas 4 0 W C P LP Propane 10 0 W C P WARNING FOR YOUR SAFETY If not installed operated and maintained in accordance with the manufacturer s instructions this produ...

Страница 9: ...nding prong from this plug Keep all electric cords away from the heated surfaces of the grill WARNING Spider And Insect Infestation Spiders and insects can nest in the burners venturi tubes of this or...

Страница 10: ...rial Numbers General Information 03 16 11 C00009652 V G I Q 4 1 0 3 R E 2 L S S V Professional Series Gas Side Burners 41 3 Grill Burners E Series Rotisserie L P Gas Stainless Steel Infrared Grill Ser...

Страница 11: ...wise to any position This control is both a gas valve and an electric switch Burners will ignite at any ON position with the automatic re ignition system If the ame goes out for any reason the burners...

Страница 12: ...ind conditions more so than the protected grill burners For this reason you should avoid using it during windy conditions Open the canopy Push in and turn the rotisserie control knob until the HIGH po...

Страница 13: ...nt them from drying out and aming If the wood chips do ame up add a small amount of water to extinguish the ame Use caution when adding water to a hot box to avoid steam burns This tray may also be ll...

Страница 14: ...ition Switch VGBQ300 2RE2 Rotisserie Grill VGIQ410 3RE2 Grill Grill Grill Rotisserie Grill VGBQ410 3RE2 Ignition Switch Light Switch Grill Grill Light Switch Grill Tru Sear Infrared Side Rear Grill Gr...

Страница 15: ...Infrared Rotisserie Ignition Switch Ignition Switch VGIQ530 4RE2 Side Rear Rotisserie Grill Side Front Grill Ignition Switch VGBQ532 3RE2 Side Front Side Rear Tru Sear Infrared Grill Rotisserie Ignit...

Страница 16: ...Access panel removed VGIQ410 3RE2 model shown Service Diagnostics and Procedures Light Transformer LED Lighting Rotisserie Valve Infrared Burner Valve Grill Igniter Light Switch Rotisserie Iginter Sw...

Страница 17: ...n Control Panel Access panel removed VGIQ412 2RE2 model shown Light Transformer LED Lighting Rotisserie Valve Rear Side Burner Valve Grill Igniter Light Switch Rotisserie Iginter Switch Grill Valve Gr...

Страница 18: ...18 2011 Viking Preferred Service Parts Location Rear View Access panel removed VGIQ412 2RE2 model shown Service Diagnostics and Procedures Rotisserie Igniter Rotisserie Burner...

Страница 19: ...s have interior halogen canopy lights and are activated by a light switch When the switch is pressed the switch contacts close and when the switch is in the off position the contacts are open To acces...

Страница 20: ...When the end user makes a selection the spark switch closes sending voltage to the igniter generating a spark To access the spark switch 1 Access control panel components see Control Panel Components...

Страница 21: ...nd slide cover out 3 Remove screws securing module disconnect wiring and remove module 4 Reverse procedure to reassemble Verify 120 VAC input to the module from positions L1 to N Output should be posi...

Страница 22: ...w securing cover and slide out 3 Slide terminal block out for access to wiring 4 Reverse procedure to reassemble Verify 120 VAC between black and white at terminal block Verify output to the transform...

Страница 23: ...is received at the igniter from the spark module To access the igniter 1 Access control panel components see Control Panel Components Access section page 19 Disconnect wires and remove control panel 2...

Страница 24: ...ing screw and igniter from bracket pull igniter into burner box and disconnect wire from igniter 3 Reverse procedure to reassemble If the igniter fails to spark rst do a resistance check on the ignite...

Страница 25: ...glow will even out in about ve minutes To access the Rotisserie Igniter 1 Open lid and remove upper rack 2 Locate rotisserie igniter cover s Remove two screws securing igniter cover 3 Remove rack hold...

Страница 26: ...120 VAC is stepped down to 2 5 VAC to supply power to the LED lights To access the light transformer 1 Access control panel components see Control Panel Components Access section page 19 Disconnect wi...

Страница 27: ...ble verify input to terminal block and output from the terminal block to the transformer Output voltage from the transformer should be 2 5 VAC Note VGIQ410 3RE2 model shown Screws Cover Light Transfor...

Страница 28: ...vice Diagnostics and Procedures 2011 Viking Preferred Service Parts Location Burners VGIQ410 3RE2 model shown Rotisserie Igniter and Thermocouple Infrared Burner Rotisserie Burner Grill Burner Grill B...

Страница 29: ...iagnostics and Procedures 2011 Viking Preferred Service Parts Location Burners VGIQ412 2RE2 model shown Rotisserie Igniter and Thermocouple Infrared Burner Rotisserie Burner Grill Burner Side Burner G...

Страница 30: ...w at burner Visually look for a spark at the burner If no spark is found ohm igniter and verify no cracks If igniter is proper verify spark switch wiring and power source If power is supplied spark wi...

Страница 31: ...gas ow at burner Visually look for a spark at the burner If no spark is found ohm igniter and verify no cracks If igniter is proper verify wiring and ignition module The spark module receives 120 VAC...

Страница 32: ...to continue To troubleshoot the thermocouple rst isolate the source of the issue If the burner will light but will not sustain a ame verify tank pressure regulator gas valve and thermocouple is prope...

Страница 33: ...in parts the skewer and the motor The skewer is assembled into motor gear box The 120 VAC motor will drive the skewer once the switch is turned to the on position To access the motor 1 Unplug the moto...

Страница 34: ...en in the off position and read 0 in the on position If switch is good verify wiring If wiring is good and bulb still does not illuminate replace socket Grill Canopy The E series has a spring loaded c...

Страница 35: ...are accessible Note the location of the spring in the spring index and canopy top end mount prior to removal 5 Reverse procedure to reassemble Note VGIQ410 3RE2 model shown WARNING To avoid risk of e...

Страница 36: ...odor present Burner inlet Air shutter Verify no obstructions are present Verify proper adjustment Low heat with knob on High Gas supply line Gas supply Gas pressure Burner Ori ce Air Shutter Verify th...

Страница 37: ...SB REAR VALVE SWITCH SB FRONT VALVE ROTISSERIE PUSH BUTTON SWITCH SWITCH LH GRILL VALVE GRD SPARK TO GRD SBR SBF RPB LFG CG LHS RHS GND SWITCH CNTR GRILL VALVE SWITCH ROTISSERIE PUSH BUTTON SWITCH RI...