26
Service Diagnostics and Procedures
© 2011 Viking Preferred Service
Rotisserie Igniter (continued)
6.
Locate and remove screw securing rear of
igniter(s).
7. Remove
igniter.
8. Reverse procedure to reassemble.
If the igniter fails to spark, first do a resistance
check on the igniter. If the igniter shows 0
ї
, ensure
power to the igniter from the module. If power is
supplied to the igniter and no spark, replace the
igniter.
Light Transformer
The unit uses a step down transformer to supply
power for the LED lights. The 120 VAC is stepped
down to 2.5 VAC to supply power to the LED lights.
To access the light transformer:
1.
Access control panel components (
see Control
Panel Components Access section, page 19)
.
Disconnect wires and remove control panel.
2.
Remove the screws securing the landing ledge
and remove landing ledge. Locate light
transformer cover.
3. Remove the screws securing the transformer to
the cover.
Note
: VGIQ410-3RE2 model shown
Rear View
Test Points
WARNING
To avoid risk of electrical shock, personal injury, or death, disconnect gas supply and electrical power to unit
before servicing. After servicing, reconnect electrical power and gas supply.
Landing Ledge
Screw
Screw
Light Transformer Cover
Screws
Cover
Screw