Viking VGBQ300-2RE2 Скачать руководство пользователя страница 1

Service
Manual

7KLVPDQXDOLVWREHXVHGE\TXDOL¿HGDSSOLDQFHWHFKQLFLDQVRQO\
9LNLQJGRHVQRWDVVXPHDQ\UHVSRQVLELOLW\IRUSURSHUW\GDPDJH
RUSHUVRQDOLQMXU\IRULPSURSHUVHUYLFHSURFHGXUHVGRQHE\DQ
XQTXDOL¿HGSHUVRQ

3UHIHUUHG6HUYLFH

7KLV%DVH0DQXDOFRYHUVJHQHUDODQG

VSHFL¿FLQIRUPDWLRQLQFOXGLQJEXWQRW

OLPLWHGWRWKHIROORZLQJPRGHOV

VGBQ300-2RE2
VGBQ410-3RE2
VGBQ412-2RE2

VGIQ410-3RE2
VGIQ412-2RE2

VGBQ530-4RE2
VGBQ532-3RE2

VGIQ530-4RE2
VGIQ532-3RE2

 

60

-XO\

Outdoor Gas Grills

(E-Series)

(VGBQ530-4RE2 model shown)

Содержание VGBQ300-2RE2

Страница 1: ...U LPSURSHU VHUYLFH SURFHGXUHV GRQH E DQ XQTXDOL HG SHUVRQ 3UHIHUUHG 6HUYLFH 7KLV DVH 0DQXDO FRYHUV JHQHUDO DQG VSHFL F LQIRUPDWLRQ LQFOXGLQJ EXW QRW OLPLWHG WR WKH IROORZLQJ PRGHOV VGBQ300 2RE2 VGBQ41...

Страница 2: ...2 Lighting Infrared Rotisserie Burner 12 Before You Begin 12 Canopy Thermometers If Applicable 13 Smoker Burner and Smoker Box 13 Wood Chip Use in Smoker Box 13 Rotisserie 13 SERVICE DIAGNOSTICS AND P...

Страница 3: ...safety messages will be preceded by a safety alert symbol and the word DANGER WARNING or CAUTION These words mean All safety messages will identify the hazard tell you how to reduce the chance of inju...

Страница 4: ...duct extends beyond normal residential use Examples are but not limited to bed and breakfasts re stations private clubs churches etc This warranty excludes all commercial locations such as restaurants...

Страница 5: ...establish warranty period The return of the Owner Registration Card is not a condition of warranty coverage You should however return the Owner Registration Card so that Viking Range Corporation can c...

Страница 6: ...120 VAC 60HZ 2 61 0 cm power cord supply cord with 3 prong grounded plug attached to rotisserie motor Grill burner rating 29 000 BTU Nat 28 000 BTU LP 7 3 kW Nat 6 5 kW LP TruSear burner rating If ap...

Страница 7: ...unded plug attached to grill 120 VAC 60HZ 2 61 0 cm power cord supply cord with 3 prong grounded plug attached to rotisserie motor Grill burner rating 29 000 BTU Nat 28 000 BTU LP 7 3 kW Nat 6 5 kW LP...

Страница 8: ...s Goods Gas Manifold Pressure Natural gas 4 0 W C P LP Propane 10 0 W C P WARNING FOR YOUR SAFETY If not installed operated and maintained in accordance with the manufacturer s instructions this produ...

Страница 9: ...nding prong from this plug Keep all electric cords away from the heated surfaces of the grill WARNING Spider And Insect Infestation Spiders and insects can nest in the burners venturi tubes of this or...

Страница 10: ...rial Numbers General Information 03 16 11 C00009652 V G I Q 4 1 0 3 R E 2 L S S V Professional Series Gas Side Burners 41 3 Grill Burners E Series Rotisserie L P Gas Stainless Steel Infrared Grill Ser...

Страница 11: ...wise to any position This control is both a gas valve and an electric switch Burners will ignite at any ON position with the automatic re ignition system If the ame goes out for any reason the burners...

Страница 12: ...ind conditions more so than the protected grill burners For this reason you should avoid using it during windy conditions Open the canopy Push in and turn the rotisserie control knob until the HIGH po...

Страница 13: ...nt them from drying out and aming If the wood chips do ame up add a small amount of water to extinguish the ame Use caution when adding water to a hot box to avoid steam burns This tray may also be ll...

Страница 14: ...ition Switch VGBQ300 2RE2 Rotisserie Grill VGIQ410 3RE2 Grill Grill Grill Rotisserie Grill VGBQ410 3RE2 Ignition Switch Light Switch Grill Grill Light Switch Grill Tru Sear Infrared Side Rear Grill Gr...

Страница 15: ...Infrared Rotisserie Ignition Switch Ignition Switch VGIQ530 4RE2 Side Rear Rotisserie Grill Side Front Grill Ignition Switch VGBQ532 3RE2 Side Front Side Rear Tru Sear Infrared Grill Rotisserie Ignit...

Страница 16: ...Access panel removed VGIQ410 3RE2 model shown Service Diagnostics and Procedures Light Transformer LED Lighting Rotisserie Valve Infrared Burner Valve Grill Igniter Light Switch Rotisserie Iginter Sw...

Страница 17: ...n Control Panel Access panel removed VGIQ412 2RE2 model shown Light Transformer LED Lighting Rotisserie Valve Rear Side Burner Valve Grill Igniter Light Switch Rotisserie Iginter Switch Grill Valve Gr...

Страница 18: ...18 2011 Viking Preferred Service Parts Location Rear View Access panel removed VGIQ412 2RE2 model shown Service Diagnostics and Procedures Rotisserie Igniter Rotisserie Burner...

Страница 19: ...s have interior halogen canopy lights and are activated by a light switch When the switch is pressed the switch contacts close and when the switch is in the off position the contacts are open To acces...

Страница 20: ...When the end user makes a selection the spark switch closes sending voltage to the igniter generating a spark To access the spark switch 1 Access control panel components see Control Panel Components...

Страница 21: ...nd slide cover out 3 Remove screws securing module disconnect wiring and remove module 4 Reverse procedure to reassemble Verify 120 VAC input to the module from positions L1 to N Output should be posi...

Страница 22: ...w securing cover and slide out 3 Slide terminal block out for access to wiring 4 Reverse procedure to reassemble Verify 120 VAC between black and white at terminal block Verify output to the transform...

Страница 23: ...is received at the igniter from the spark module To access the igniter 1 Access control panel components see Control Panel Components Access section page 19 Disconnect wires and remove control panel 2...

Страница 24: ...ing screw and igniter from bracket pull igniter into burner box and disconnect wire from igniter 3 Reverse procedure to reassemble If the igniter fails to spark rst do a resistance check on the ignite...

Страница 25: ...glow will even out in about ve minutes To access the Rotisserie Igniter 1 Open lid and remove upper rack 2 Locate rotisserie igniter cover s Remove two screws securing igniter cover 3 Remove rack hold...

Страница 26: ...120 VAC is stepped down to 2 5 VAC to supply power to the LED lights To access the light transformer 1 Access control panel components see Control Panel Components Access section page 19 Disconnect wi...

Страница 27: ...ble verify input to terminal block and output from the terminal block to the transformer Output voltage from the transformer should be 2 5 VAC Note VGIQ410 3RE2 model shown Screws Cover Light Transfor...

Страница 28: ...vice Diagnostics and Procedures 2011 Viking Preferred Service Parts Location Burners VGIQ410 3RE2 model shown Rotisserie Igniter and Thermocouple Infrared Burner Rotisserie Burner Grill Burner Grill B...

Страница 29: ...iagnostics and Procedures 2011 Viking Preferred Service Parts Location Burners VGIQ412 2RE2 model shown Rotisserie Igniter and Thermocouple Infrared Burner Rotisserie Burner Grill Burner Side Burner G...

Страница 30: ...w at burner Visually look for a spark at the burner If no spark is found ohm igniter and verify no cracks If igniter is proper verify spark switch wiring and power source If power is supplied spark wi...

Страница 31: ...gas ow at burner Visually look for a spark at the burner If no spark is found ohm igniter and verify no cracks If igniter is proper verify wiring and ignition module The spark module receives 120 VAC...

Страница 32: ...to continue To troubleshoot the thermocouple rst isolate the source of the issue If the burner will light but will not sustain a ame verify tank pressure regulator gas valve and thermocouple is prope...

Страница 33: ...in parts the skewer and the motor The skewer is assembled into motor gear box The 120 VAC motor will drive the skewer once the switch is turned to the on position To access the motor 1 Unplug the moto...

Страница 34: ...en in the off position and read 0 in the on position If switch is good verify wiring If wiring is good and bulb still does not illuminate replace socket Grill Canopy The E series has a spring loaded c...

Страница 35: ...are accessible Note the location of the spring in the spring index and canopy top end mount prior to removal 5 Reverse procedure to reassemble Note VGIQ410 3RE2 model shown WARNING To avoid risk of e...

Страница 36: ...odor present Burner inlet Air shutter Verify no obstructions are present Verify proper adjustment Low heat with knob on High Gas supply line Gas supply Gas pressure Burner Ori ce Air Shutter Verify th...

Страница 37: ...SB REAR VALVE SWITCH SB FRONT VALVE ROTISSERIE PUSH BUTTON SWITCH SWITCH LH GRILL VALVE GRD SPARK TO GRD SBR SBF RPB LFG CG LHS RHS GND SWITCH CNTR GRILL VALVE SWITCH ROTISSERIE PUSH BUTTON SWITCH RI...