0478 131 9923 B - EN
144
– Message is active
– Flap open or not present
– Docking station not connected to power
supply
– Power failure
Remedy:
– Allow the battery to finish charging
– Switch on automatic mowing (
– No further action necessary, mowing
operations are automatically distributed
over the week – if necessary, start the
mowing operation with the "Mowing"
command (
– Rectify displayed fault and confirm the
– Close the flap (
– Check power supply to the docking
station (
– Check power supply. When the robotic
mower detects a wire signal again after
a periodic check, it resumes the
interrupted mowing operation. This
means that it can take several minutes
before mowing operation is
automatically resumed following the
power failure. The intervals between
the individual periodic checks become
lager, the longer the power failure lasts.
Fault:
The robotic mower fails to mow after the
commands "Start mowing" or "Start time-
delayed mowing" have been called up
Possible cause:
– Insufficient battery charge
– Rain detected
– Flap not closed or not present
– Message is active
Remedy:
– Set the rain sensor (
– Rectify displayed fault and confirm the
message with OK (
Fault:
The robotic mower is not working and
nothing is shown in the display
Possible cause:
– Machine is in standby
– Battery defective
Remedy:
– Press any button to wake up the robotic
mower – the status screen appears
(
– Replace the battery (
#
)
Fault:
The robotic mower is noisy and vibrates
Possible cause:
– Mowing blade is damaged
– Mowing deck is very dirty
Remedy:
– Replace the mowing blade – remove
(
#
)
Fault:
Poor mulching or mowing result
Possible cause:
– Grass is too high in relation to the
cutting height
– Lawn is extremely wet
– Mowing blade is blunt or worn
– Active times insufficient, mowing
duration too short
– Size of mowing area set incorrectly
– Mowing area with very high grass
– Long periods of rain
Remedy:
– Adjust the cutting height (
(
#
)
– Extend or add active times (
– For neat mowing results, the robotic
mower needs up to 2 weeks, depending
on the size of the lawn.
Fault:
Display in a foreign language
Possible cause:
– Language setting has been changed
Remedy:
Fault:
Brown (earthy) patches appear in the
mowing area
Possible cause:
– Mowing duration is too long in relation
to the mowing area
– Perimeter wire has been routed with
excessively tight radii
– Size of mowing area set incorrectly
Remedy:
– Reduce the mowing duration (
– Correct the routing of the perimeter wire
Содержание MI 422
Страница 2: ...0478 131 9923 B D16 Eco DS 2016 02 2016 VIKING GmbH A 6336 Langkampfen Kufstein...
Страница 3: ...1 0478 131 9923 B 1...
Страница 4: ...0478 131 9923 B 2 2...
Страница 154: ...0478 131 9923 B EN 152...
Страница 232: ...0478 131 9923 B FR 230...
Страница 308: ...0478 131 9923 B NL 306...
Страница 387: ...385 DE EN FR NL IT 0478 131 9923 B IT...
Страница 388: ...0478 131 9923 B MI 422 MI 422 P B...