Route the perimeter wire (2) in front of and
behind the docking station (1) for
0.6 m
in
a straight line and at right angles to the
floor plate. Then follow the edge of the
mowing area with the perimeter wire.
External docking station:
Route the perimeter wire (2) in front of and
behind the docking station (1) with a
clearance (A) and at right angles to the
floor plate. Then install a corridor.
(
A freely travellable minimum clearance (B)
must be available for the robotic mower to
the side of the ground plate.
A
=
0,5 m
B
=
0,34 m
Then follow the edge of the mowing area
with the perimeter wire.
Wire routing around the mowing area:
Route the perimeter wire (1) around the
mowing area and around any obstacles
(
11.8) and fasten it to the ground using
fixing pins (2). Check the clearances using
the iRuler. (
Avoid routing at acute angles (less than
90°). In acutely angled lawn corners,
fasten the perimeter wire (1) to the ground
with fixing pins (2) as illustrated.
If the staggered drive home
(corridor) is used, the perimeter
wire must be routed at least
1.5 m
in front of and behind the docking
station in a straight line and at right
angles to the floor plate. (
Further information on installation
of the external docking station is
contained in the Installation
examples section. (
Содержание MI 422
Страница 2: ...0478 131 9923 B D16 Eco DS 2016 02 2016 VIKING GmbH A 6336 Langkampfen Kufstein...
Страница 3: ...1 0478 131 9923 B 1...
Страница 4: ...0478 131 9923 B 2 2...
Страница 154: ...0478 131 9923 B EN 152...
Страница 232: ...0478 131 9923 B FR 230...
Страница 308: ...0478 131 9923 B NL 306...
Страница 387: ...385 DE EN FR NL IT 0478 131 9923 B IT...
Страница 388: ...0478 131 9923 B MI 422 MI 422 P B...