Disassembly Procedures
©2007 Viking Preferred Service
53
WARNING
To avoid risk of electrical shock, personal injury, or death, disconnect power to unit before servicing,
unless testing requires power.
Condenser Fan Motor and Blade Removal
Condition Requirements:
Access to Machine Compartment
1. Disconnect connector from condenser motor.
2. Remove two screws from mounting brackets
attached to motor.
3. Remove motor and fan blade out the rear of shroud.
4. Remove the retainer nut to remove fan blade.
5. Reverse procedure to reassemble.
Condensate Drip Pan Removal
Condition Requirements:
Compressor Removed
Condenser Fan Motor Removed
Water Valve Assembly Removed
NOTE:
Condensate drip pan may have water in it. Wipe
up all water prior to removal.
1. Bend copper tubing up out of condensate pan to
allow removal of condensate pan.
2. Reverse procedure for installation.
Condenser Removal
Condition Requirements:
Condenser Fan Motor Removed
Compressor Removed
NOTE:
Condenser is removed by laying unit on its back
and requires at least two people to do this
procedure.
1. Follow reclaiming procedures in Service Procedures
section of this manual.
2. With the help of second person lay unit on back on
raised surface.
3. Remove four torx head screws holding basepan to
cabinet.
4. Lift and remove basepan to access condenser coil.
5. Unbraze condenser coil from connecting tubing.
6. Remove condenser coil by unsnapping it from
retainers in basepan.
7. Reverse procedure for installation.