Coding in
the as
delivered
condition
Address:
value
Function mode
Coding
change
Address:
value
Possible change
32:0
Signal "External lock-
out" on circulation
pumps: All pumps are
controlled
32:1
to
32:15
Signal "External lockout"
on circulation pumps:
See the following table
Coding
Internal
circula-
tion pump
Heating cir-
cuit pump
Heating cir-
cuit without
mixer
Heating circuit
pump
Heating circuit
with mixer
Cylinder loading
pump
0
Control
funct.
Control funct.
Control funct.
Control funct.
1
Control
funct.
Control funct.
Control funct.
OFF
2
Control
funct.
Control funct.
OFF
Control funct.
3
Control
funct.
Control funct.
OFF
OFF
4
Control
funct.
OFF
Control funct.
Control funct.
5
Control
funct.
OFF
Control funct.
OFF
6
Control
funct.
OFF
OFF
Control funct.
7
Control
funct.
OFF
OFF
OFF
8
OFF
Control funct.
Control funct.
Control funct.
9
OFF
Control funct.
Control funct.
OFF
10
OFF
Control funct.
OFF
Control funct.
11
OFF
Control funct.
OFF
OFF
12
OFF
OFF
Control funct.
Control funct.
13
OFF
OFF
Control funct.
OFF
14
OFF
OFF
OFF
Control funct.
15
OFF
OFF
OFF
OFF
Code 2
(cont.)
45
Coding
56
92
550
GB
Содержание VITODENS 300 WB3A
Страница 10: ...Opening the control unit housing 10 5862 570 GB...
Страница 14: ...Closing control unit housing and inserting user interface 14 5862 570 GB...
Страница 122: ...Temperature profile Factory set code F1 6 to F1 15 Control functions cont 106 Function description 5692 550 GB...
Страница 125: ...A1 Main PCB A2 Mains supply unit Connection and wiring diagrams external connections 109 Designs 5692 550 GB...
Страница 129: ...Parts lists cont 113 Parts lists 5692 550 GB...
Страница 130: ...Parts lists cont 114 Parts lists 5692 550 GB...
Страница 131: ...Parts lists cont 115 Parts lists 5692 550 GB...
Страница 132: ...Parts lists cont 116 Parts lists 5692 550 GB...
Страница 133: ...Parts lists cont 117 Parts lists 5692 550 GB...
Страница 145: ...129 5692 550 GB...
Страница 146: ...130 5692 550 GB...
Страница 147: ...131 5692 550 GB...