Displayed
fault code
Const.
Weat-
her-
comp.
System
character-
istics
Cause
Remedy
C6
X
Control
mode,
max. pump
speed
Communication
fault - variable
speed heating cir-
cuit pump, heating
circuit M2
Check coding
address E5
settings;
check the
heating cir-
cuit pump
DIP switch
settings
C7
X
X
Control
mode,
max. pump
speed
Communication
fault - variable
speed heating cir-
cuit pump, heating
circuit A1
Check coding
address E5
settings;
check the
heating cir-
cuit pump
DIP switch
settings
Cd
X
X
Control
mode
Communication
fault Vitocom 100
(KM BUS)
Check con-
nections and
Vitocom 100
CE
X
X
Control
mode
Communication
fault - ext. exten-
sion
Check con-
nections and
coding
address 2E
settings
CF
X
Control
mode
Communications
fault - LON commu-
nication module
Replace the
LON commu-
nication mod-
ule
dA
X
Control
mode with-
out room
influence
Room temperature
sensor heating cir-
cuit A1 shorted out
Check the
room tem-
perature sen-
sor - heating
circuit A1
db
X
Heating circuit M2
room temperature
sensor shorted out
Check the
room tem-
perature sen-
sor - heating
circuit M2
Checking and acknowledging faults
(cont.)
80
Troubleshooting
56
92
550
GB
Содержание VITODENS 300 WB3A
Страница 10: ...Opening the control unit housing 10 5862 570 GB...
Страница 14: ...Closing control unit housing and inserting user interface 14 5862 570 GB...
Страница 122: ...Temperature profile Factory set code F1 6 to F1 15 Control functions cont 106 Function description 5692 550 GB...
Страница 125: ...A1 Main PCB A2 Mains supply unit Connection and wiring diagrams external connections 109 Designs 5692 550 GB...
Страница 129: ...Parts lists cont 113 Parts lists 5692 550 GB...
Страница 130: ...Parts lists cont 114 Parts lists 5692 550 GB...
Страница 131: ...Parts lists cont 115 Parts lists 5692 550 GB...
Страница 132: ...Parts lists cont 116 Parts lists 5692 550 GB...
Страница 133: ...Parts lists cont 117 Parts lists 5692 550 GB...
Страница 145: ...129 5692 550 GB...
Страница 146: ...130 5692 550 GB...
Страница 147: ...131 5692 550 GB...