Displayed
fault code
Const.
Weat-
her-
comp.
System
character-
istics
Cause
Remedy
FF
X
X
Burner
blocked
Internal fault
Remove EMC
interference.
If the equip-
ment will not
restart, check
the boiler
coding card
and replace,
or replace the
control unit.
Repairs
Checking the outside temperature sensor (weather-compen-
sated control units)
1.
Pull plug X3 from the control unit.
Checking and acknowledging faults
(cont.)