Vertical flue systems
Position
Minimum spacing
mm
o
From adjacent wall
300
p
From adjacent opening window
1000
q
From another terminal
600
r
Minimum height
300
Flue Terminal Location
Detailed recommendations for flue
installation are given in BS 5440:1.
The following notes are for general
guidance.
&
The boiler must be installed so that
the terminal is exposed to external
air.
&
It is important that the position of the
terminal allows free passage of air
across it at all times.
Installation Requirements
(cont.)
19
Preparing for installation
58
62
670
GB
Installation