129
Parameter
Code
Factory setting
Commission-
ing
Operating status for external changeover
7012
2
Effect of external blocking on pumps/compressor
701A
0
Duration of external changeover
7013
8 h
Effect of external demand on heat pump/heating cir-
cuits
7014
4
Effect of ext. blocking on heat pump/heating circuits
7015
4
Vitocom 100
7017
0
Effect of external blocking on pumps/compressor
701A
0
Common system flow temperature sensor
701B
1
Compressor
Parameter
Code
Factory setting
Commission-
ing
Enable compressor
5000
1
Evaporator temperature for defrost end
5010
200 (
≙
20 °C
Output compressor stage
5030
Rated heating output ac-
cording to type plate
External heat source
Parameter
Code
Factory setting
Commission-
ing
Enable external heat source
7B00
0
Priority ext. heat source/instant. heating water heater
7B01
1
Dual mode temperature external heat source
7B02
100 (
≙
10 °C)
Enable external heat source for DHW heating
7B0D
0
DHW
Parameter
Code
Factory setting
Commission-
ing
Set DHW temperature
6000
500 (
≙
50 °C)
Min. DHW temperature
6005
100 (
≙
10 °C)
Max. DHW temperature
6006
600 (
≙
60 °C)
Hysteresis DHW temperature heat pump
6007
70 (
≙
7 K)
Hysteresis DHW temperature booster heater
6008
100 (
≙
10 K)
Start optimisation for DHW heating
6009
0
Stop optimisation for DHW heating
600A
0
Set DHW temperature 2
600C
600 (
≙
60 °C)
Temperature sensor at bottom of DHW cylinder
600E
0
Enable booster heaters for DHW heating
6014
0
Enable electric heaters for DHW heating
6015
1
Priority DHW heating with combi cylinder
6016
0
Start attempts for DHW after high pressure shutdown
6017
1
Operating mode cylinder primary pump
6020
Do not adjust.
Solar
Parameter
Code
Factory setting
Commission-
ing
Type solar control unit
7A00
0
Commissioning/service reports
Control parameter report
(cont.)
5692878
Appendix
Содержание Vitocal 350-A AWHI 351.A14
Страница 22: ...22 Fig 13 Installation sequence Type AWHI 351 A only Fitting the supplied floor mat 5692878 Installation ...
Страница 26: ...26 3x 8 9 3x 3x 3x Fig 17 Installation sequence Fitting the outer panels cont 5692878 Installation ...
Страница 27: ...27 10 3x 3x 2x 11 Fig 18 Installation sequence Fitting the outer panels cont 5692878 Installation ...
Страница 30: ...30 Type AWHI 351 A 1 Fig 22 Installation sequence Siting the heat pump cont 5692878 Installation ...
Страница 66: ...66 Fitting the front panel 1 2 Fig 64 Installation sequence Closing the heat pump cont 5692878 Installation ...
Страница 82: ...82 Troubleshooting Repairs cont 5692878 Maintenance ...
Страница 101: ...101 Parts list type AWHI 351 A Heat pump module cont 5692878 Components ...
Страница 104: ...104 Parts list type AWHI 351 A Base frame cont 5692878 Components ...
Страница 110: ...110 Silencer hood 0001 0002 0001 Fig 86 Parts list type AWHO 351 A Casing cont 5692878 Components ...
Страница 114: ...114 0007 0007 0003 0005 0003 0002 0001 0006 0005 0008 Fig 88 Parts list type AWHO 351 A Air module 5692878 Components ...
Страница 125: ...125 Parts list type AWHO 351 A Heat pump module cont 5692878 Components ...