47
Main PCB (operational components 230 V~)
Information regarding the connection values
■
The specified output is the recommended connected
load.
■
The total output of all components connected directly
to the heat pump control unit (e.g. pumps, valves,
message facilities, contactors) must not exceed
1000 W.
If the total output is < 1000 W, the individual rating of
a component (e.g. pump, valve, message facility,
contactor) can be greater than specified. However,
the breaking capacity of the corresponding relay
must not be exceeded.
■
The stated current indicates the max. switching cur-
rent of the switching contact (observe the total cur-
rent of 5 A).
■
Controls for external heat source and central fault
messages are unsuitable for safety LV.
Set the required parameters during commissioning;
see from page 73.
Plug
sYA
Terminals
Function
Explanation
211.1
Fan
Connection values:
■
Output: 200 W
■
Voltage: 230 V~
■
Max. switching current: 4(2) A
211.2
Secondary pump
■
In systems without a heating water buffer cylinder, no
other heating circuit pump is required (see terminal
212.2).
■
Connect the temperature limiter to restrict the maxi-
mum temperature for underfloor heating systems (if
installed) in series (see the following chapter).
Connection values:
■
Output: 130 W
■
Voltage: 230 V~
■
Max. switching current: 4(2) A
211.3
r
1.
Control of instantaneous heating wa-
ter heater, stage 1
Connection values:
■
Output: 10 W
■
Voltage: 230 V~
■
Max. switching current: 4(2) A
See installation instructions for instantaneous heating
water heater and switching module.
211.4
Circulation pump for cylinder heating
Connection values:
■
Output: 130 W
■
Voltage: 230 V~
■
Max. switching current: 4(2) A
Installation sequence
Heat pump control unit electrical connections
(cont.)
5692878
Installation
Содержание Vitocal 350-A AWHI 351.A14
Страница 22: ...22 Fig 13 Installation sequence Type AWHI 351 A only Fitting the supplied floor mat 5692878 Installation ...
Страница 26: ...26 3x 8 9 3x 3x 3x Fig 17 Installation sequence Fitting the outer panels cont 5692878 Installation ...
Страница 27: ...27 10 3x 3x 2x 11 Fig 18 Installation sequence Fitting the outer panels cont 5692878 Installation ...
Страница 30: ...30 Type AWHI 351 A 1 Fig 22 Installation sequence Siting the heat pump cont 5692878 Installation ...
Страница 66: ...66 Fitting the front panel 1 2 Fig 64 Installation sequence Closing the heat pump cont 5692878 Installation ...
Страница 82: ...82 Troubleshooting Repairs cont 5692878 Maintenance ...
Страница 101: ...101 Parts list type AWHI 351 A Heat pump module cont 5692878 Components ...
Страница 104: ...104 Parts list type AWHI 351 A Base frame cont 5692878 Components ...
Страница 110: ...110 Silencer hood 0001 0002 0001 Fig 86 Parts list type AWHO 351 A Casing cont 5692878 Components ...
Страница 114: ...114 0007 0007 0003 0005 0003 0002 0001 0006 0005 0008 Fig 88 Parts list type AWHO 351 A Air module 5692878 Components ...
Страница 125: ...125 Parts list type AWHO 351 A Heat pump module cont 5692878 Components ...