ROLL GROOVE SPECIFICATIONS
STEEL PIPE AND ALL MATERIALS
GROOVED WITH “ES” ROLLS
1
2
3
4
5
6
7
8
Nom.
Size
In.
mm
Dimensions – Inches/millimeters
Pipe Outside Dia. O.D.
Gasket Seat
A
Groove Width
B
Groove Dia.
C
Grv.
Depth
(ref.)
D
Nom.
Min.
Allow.
Wall
Thick.
T
Max.
Allow.
Flare
Dia.
Basic
Tolerance
+ -
Basic
Tol.
+0.000
+0.00
Basic
Tol.
-0.000
-0.00
Basic
Tol.
+0.000
+0.00
2
2.375
+0.024 –0.024
0.572
–0.020
0.250
+0.015
2.250
–0.015
0.063
0.065
2.48
50
60.3
+0.61
–0.61
14.53
–0.51
6.35
+0.38
57.15
–0.38
1.60
1.65
63.0
21/2
2.875
+0.029 –0.029
0.572
–0.020
0.250
+0.015
2.720
–0.018
0.078
0.083
2.98
65
73.0
+0.74
–0.74
14.53
–0.51
6.35
+0.38
69.09
–0.46
1.98
2.11
75.7
3
3.500
+0.035 –0.031
0.572
–0.020
0.250
+0.015
3.344
–0.018
0.078
0.083
3.60
80
88.9
+0.89
–0.79
14.53
–0.51
6.35
+0.38
84.94
–0.46
1.98
2.11
78.7
4
4.500
+0.045 –0.031
0.610
–0.020
0.300
+0.020
4.334
–0.020
0.083
0.083
4.60
100
114.3
+1.14
–0.79
15.49
–0.51
7.62
+0.51
110.08
–0.51
2.11
2.11
116.8
6
6.625
+0.063 –0.031
0.610
–0.020
0.300
+0.020
6.455
–0.022
0.085
0.109
6.73
150
168.3
+1.60
–0.79
15.49
–0.51
7.62
+0.51
163.96
–0.56
2.16
2.77
170.9
8
8.625
+0.063 –0.031
0.719
–0.020
0.390
+0.020
8.441
–0.025
0.092
0.109
8.80
200
219.1
+1.60
–0.79
18.26
–0.51
9.91
+0.51
214.40
–0.64
2.34
2.77
223.5
10
10.750 +0.063 –0.031
0.719
–0.020
0.390
+0.020 10.562
–0.027
0.094
0.134
10.92
250
273.0
+1.60
–0.79
18.26
–0.51
9.91
+0.51
268.28
–0.69
2.39
3.40
277.4
12
12.750 +0.063 –0.031
0.719
–0.020
0.390
+0.020
12.531
–0.030
0.109
0.156
12.92
300
323.9
+1.60
–0.79
18.26
–0.51
9.91
+0.51
318.29
–0.76
2.77
3.96
328.2
“ES” ROLL GROOVE SPECIFICATIONS
COLUMN 1: Nominal IPS pipe size.
Nominal metric (ISO) pipe size .
COLUMN 2: IPS outside diameter.
Metric (ISO) outside diameter . The outside diameter of roll grooved pipe shall not vary more
than the tolerance listed . For IPS pipe, the maximum allowable tolerance from square cut ends is 0 .030” for 3/4 - 31/2” (20 - 90
mm); 0 .045: for 4 - 6” (100 - 150 mm); and 0 .060” for sizes 8” O .D . (200 mm) and above measured from true square line . For
(ISO) metric pipe, the maximum allowable tolerance from square cut ends is 0 .76 mm for sizes 20 mm - 80 mm; 1 .14 mm for sizes
100 mm - 150 mm; and 1 .52 mm for sizes 200 mm and above, measured from the true square line .
COLUMN 3: Gasket seat:
the pipe surface shall be free from indentations, roll marks, and projections from the end of the pipe to
the groove, to provide a leak-tight seal for the gasket . All loose paint, scale, dirt, chips, grease and rust must be removed . Square
cut pipe must be used with FlushSeal
®
and EndSeal
®
gaskets . Gasket seat “A” is measured from the end of the pipe . IMPORTANT:
Roll grooving may result in unacceptable pipe end flare . (See column 8 .)
COLUMN 4: Groove width:
bottom of groove to be free of loose dirt, chips, rust and scale that may interfere with proper coupling
assembly . Corners at bottom of roll groove must have a radius of the following dimensions . For IPS pipe, 0 .04R on 11/2 - 12” (40 -
300 mm) . For (ISO) metric pipe, 1 .2R mm on 20 - 300 mm .
COLUMN 5: Groove outside diameter:
the groove must be uniform depth for the entire pipe circumference . Groove must be
maintained within the “C” diameter tolerance listed .
COLUMN 6: Groove depth:
for reference only . Groove must conform to the groove diameter “C” listed .
COLUMN 7: Minimum allowable wall thickness:
this is the minimum wall thickness which may be grooved .
COLUMN 8: Maximum allowable pipe end flare diameter.
Measured at the most extreme pipe end diameter square cut or
beveled .
A
B
D
B
T
C
OD
F
TM-VE416FS/FSD_33
TM-VE416FS/FSD
OPERATING AND MAINTENANCE INSTRUCTIONS MANUAL
www.victaulic.com
VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.
REV_A