8.
Tighten the four (4) set screws as shown to
secure the tool on the support arms .
9.
Install the two (2) adjustable legs completely
into the sockets of the upper leg and finger
tighten the hex bolts .
10.
Insert top of leg assembly fully into the
socket under tool head assembly . Rotate the
assembly so it fully seats in the socket . The
hex head bolts on the legs should be toward
the back of the machine (toward power drive) .
Tighten hex head bolt using a wrench .
11.
Level the tool front to back . The top of the
cylinder mounting plate is a good location to
measure level .
12.
Loosen hex bolts to release lower legs (2)
and allow them to drop down to floor . Turn leg
pads at bottom until they are resting flat on the
floor and tighten hex bolts with the tool in a level
position .
13.
Mount the hand pump/pump support
assembly . Tighten the hand knob and then
tighten the wing set screw on the underside of
the pump support as shown .
14.
Connect the hydraulic hose from the hand
pump to the power cylinder using the quick
connections provided .
TM-VE416FS/FSD_8
TM-VE416FS/FSD
OPERATING AND MAINTENANCE INSTRUCTIONS MANUAL
www.victaulic.com
VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.
REV_A