ROLL GROOVE SPECIFICATIONS (CONT.)
STEEL PIPE AND ALL MATERIALS
GROOVED WITH STANDARD AND “RX” ROLLS
1
2
3
4
5
6
7
8
Nom.
Pipe
Size
In./mm
Dimensions – Inches/millimeters
Pipe Outside Dia.
Gasket
Seat A
±0.03
±0.76
Groove
Width B
±0.03
±0.76
Groove Dia. C
Grv.
Depth
D
(ref.)
Nom.
Min. Allow.
Wall Thk.
T
Max.
Allow.
Flare
Dia.
Basic
Tolerance
+ -
Basic
Tol.
+0.000
+0,00
10
10.750
0.063
0.031
0.750
0.469
10.562
–0.027
0.094
0.134
10.92
250
273.0
1.60
0.79
19.05
11.91
268.28
-0.69
2.39
3.40
277.4
12 O.D.
12.000
0.063
0.031
0.750
0.469
11.781
–0.030
0.109
0.156
12.17
304.8
1.60
0.79
19.05
11.91
299.24
-0.76
2.77
3.96
309.1
12
12.750
0.063
0.031
0.750
0.469
12.531
–0.030
0.109
0.156
12.92
300
323.9
1.60
0.79
19.05
11.91
318.29
-0.76
2.77
3.96
328.2
14 O.D.
14.000
0.063
0.031
0.938
0.469
13.781
–0.030
0.109
0.156
14.10
355.6
1.60
0.79
23.83
11.91
350.04
–0.76
2.77
3.96
358.1
15 O.D.
15.000
0.063
0.031
0.938
0.469
14.781
–0.030
0.109
0.165
15.10
381.0
1.60
0.79
23.83
11.91
375.44
–0.76
2.77
4.19
383.5
16 O.D.
16.000
0.063
0.031
0.938
0.469
15.781
–0.030
0.109
0.165
16.10
406.4
1.60
0.79
23.83
11.91
400.84
–0.76
2.77
4.19
408.9
STANDARD ROLL GROOVE SPECIFICATION NOTES:
COLUMN 1: Nominal IPS Pipe size.
COLUMN 2: IPS outside diameter.
The outside diameter of roll grooved pipe shall not vary more than the tolerance listed . For IPS
pipe the maximum allowable tolerance from square cut ends is 0 .030” for 3/4 - 31/2”; 0 .045” for 4 - 6”; and 0 .060” for sizes 8” O .D .
and above measured from true square line .
COLUMN 3: Gasket seat.
The pipe surface shall be free from indentations, roll marks, and projections from the end of the pipe
to the groove, to provide a leak-tight seal for the gasket . All loose paint, scale, dirt, chips, grease and rust must be removed . It
continues to be Victaulic’s first recommendation that pipe be square cut . When using beveled pipe contact Victaulic for details .
Square cut pipe must be used with FlushSeal
®
and EndSeal
®
gaskets . Gasket seat “A” is measured from the end of the pipe .
IMPORTANT: Roll grooving of beveled end pipe may result in unacceptable pipe end flare . See column 8 .
COLUMN 4: Groove width.
Bottom of groove to be free of loose dirt, chips, rust and scale that may interfere with proper coupling
assembly . Corners at bottom of groove must have a radius of the following dimensions . For IPS steel pipe, .06R on 3/4 - 11/2”,
.08R on 2 - 6”, .05R on 8” and up .
COLUMN 5: Groove outside diameter.
The groove must be of uniform depth for the entire pipe circumference . Groove must be
maintained within the “C” diameter tolerance listed .
COLUMN 6: Groove depth.
For reference only . Groove must conform to the groove diameter “C” listed .
COLUMN 7: Minimum allowable wall thickness.
This is the minimum wall thickness which may be roll grooved – except PVC .
COLUMN 8: Maximum allowable pipe end flare diameter.
Measured at the most extreme pipe end diameter square cut or
beveled .
A
B
D
B
T
C
OD
F
TM-VE416FS/FSD_32
TM-VE416FS/FSD
OPERATING AND MAINTENANCE INSTRUCTIONS MANUAL
www.victaulic.com
VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.
REV_A