VibrationVIEW Help
239
© 1995-2005 Vibration Research Corporation. All rights reserved.
This code indicates that the emergency stop button was pressed, causing the controller to shut down.
The emergency stop button is an optional accessory that connects to the remote input connector on
the rear of the
VibrationVIEW
I/O unit.
7.5.23 Input Signal is Clipped
Input Signal is Clipped (
Shock Stop Code
)
This code indicates that the input signal to channel n is exceeding the allowable input voltage range of
+/- 10 volts, and is being distorted by clipping. To solve this problem, use an accelerometer with a
lower mV/G sensitivity rating.
The maximum allowable acceleration readings for various accelerometer sensitivities are shown in the
table below.
Sensitivity
Maximum Acceleration
10 mV/G
1000 G peak
20 mV/G
500 G peak
50 mV/G
200 G peak
100 mV/G
100 G peak
1000 mV/G
10 G peak
7.5.24 Invalid Remote Test
Invalid Remote Test (
Shock Stop Code
)
This code indicates that the "Remote Start/Stop" and "Remote Selection" options are both enabled but
the test number selected using the remote test selection input (Discrete Inputs 4,5,6,7) does not have
a valid test name configured for the current input settings. Select the
menu command to verify that the test names configured there are valid.
See Also:
How to use remote inputs to control VibrationVIEW
How to use remote inputs to monitor your process
7.5.25 Computer Entering Suspend Mode (copy)
Computer Entering Suspend Mode
This code is given when VibrationVIEW is running a test, the computer is running on batteries (or
UPS), and the battery level is low. The test is stopped in order to allow the computer to switch into
suspend or hibernate mode before the batteries are completely exhausted.
7.5.26 Lost Contact
Lost contact with I/O box n (
Shock Stop Code
)
This code indicates that the
VibrationVIEW
I/O box is no longer communicating with the host computer.
Verify that:
·
The Ethernet cables are connected properly.
·
The box is powered.
7.5.27 Max Starting Voltage
Max Starting Voltage (
Shock Stop Code
)
96
40
47
Содержание VibrationVIEW
Страница 15: ...Document Revision Part I ...
Страница 17: ...How To Part II ...
Страница 96: ...Menu commands Part III ...
Страница 142: ...Test Definition Part IV ...
Страница 217: ...Control Centers Part V ...
Страница 226: ...VibrationVIEW Help 213 1995 2005 Vibration Research Corporation All rights reserved See Also RecorderVIEW 309 ...
Страница 227: ...Accelerometer Toolbars Part VI ...
Страница 231: ...Stop Codes Part VII ...
Страница 263: ...Typical Views Part VIII ...
Страница 265: ...Typical Views 252 1995 2005 Vibration Research Corporation All rights reserved 8 4 Random Random CRT View ...
Страница 268: ...VibrationVIEW Help 255 1995 2005 Vibration Research Corporation All rights reserved ...
Страница 269: ...Dialog Boxes Part IX ...
Страница 303: ...Windows Elements Part X ...
Страница 309: ...APPENDIX Part XI ...
Страница 311: ...APPENDIX 298 1995 2005 Vibration Research Corporation All rights reserved ...