Vertical SUMMIT IP
Hardware Description and Installation Manual
Issue 1.2
57
6.4.4 Hybrid Station Modular Jack Wiring
Hybrid Station modular jacks are terminated with one Digital and one SLT circuit to an
RJ11 jack as shown in the chart below. For the Hybrid ports only one of the station circuits,
DKT or SLT, can be used. To wire the Hybrid Station modular jack,
1. Wire each Hybrid Station modular jack to the termination point.
2. Tag the wiring for future maintenance.
Table 6.4.4-1 Hybrid Station Modular Jack Wiring
Connector
Pin-out
Pin Number
Signal Name
RJ11
1
N/A
2
SLT-T
3,4
DKT-T, DKT-R
5
SLT-R
6
N/A
6.4.5 DKT/SLT Station Modular Jack Wiring
The last four (4) built-in Station ports of the KSUAD and KSUID provide both a Digital and
SLT port. These Station modular jacks are terminated with one Digital and one SLT circuit
to an RJ11 jack as shown in the chart below. Both the DKT and SLT interface ports can be
wired and used simultaneously. To wire these ‘combo’ Station modular jacks,
1. Wire each combo Station modular jack to the termination point.
2. Tag the wiring for future maintenance.
Table 6.4.5-1 DKT/SLT Station Modular Jack Wiring
Connector
Pin-out
Pin Number
Signal Name
RJ11
1
N/A
2
SLT-T
3,4
DKT-T, DKT-R
5
SLT-R
6
N/A