Vertical SUMMIT IP
Hardware Description and Installation Manual
Issue 1.2
79
8. S
TARTING THE
V
ERTICAL
SUMMIT
IP
8.1 Vertical SUMMIT IP System Initial Power-up
The SUMMIT IP incorporates software initialization routines to automatically configure
system gains and tones based on the Nation Code assigned in the system database. The
Nation code is the Country code used for international dialing. Generally, this will be
properly set but, prior to any other configuration, the Nation Code must be verified to match
the location of the installation. If not it can be modified and the system initialized with the
modified Nation Code.
To initialize the system, perform the following Steps:
1. Verify the SUMMIT IP KSU MBU SW1 pole#1 is OFF, and pole#2 is ON. Also verify
the AC Power switch is OFF.
2. Plug the AC power cord into the Vertical SUMMIT IP System KSUs and the AC
outlet.
3. Turn the AC Power switches on the SUMMIT IP KSU and EKSU ON.
4. Verify and, if needed, modify, the Nation Code (PGM100) with the DKT (Section
8.2.1) or run the Install Wizard (Section 8.3).
5. Reset the SUMMIT IP KSU with either the recessed Reset button or by power
cycling (turn the AC Power switch OFF then ON).
6. After the LEDs indicate normal operation, refer to section 4.4 and change the
position of the SUMMIT IP KSU MBU SW1 pole#2 to the OFF position so the
database will not initialize during future power cycling or if the system is reset.
7. If the DKT was used to set the Nation code in Step 4, run the Install Wizard then
configure the system to the customer needs.
The following sections detail how to verify and change the Nation Code and run the Install
Wizard. Once the Nation Code has been set and the system database initialized, the system
can be configured without the need to reinitialize. For detailed information on configuring the
SUMMIT IP system, refer to the SUMMIT IP Administration and Maintenance Manual.