FT-2000
Operating Manual
Vertex Standard Co., Ltd.
109
The Time-Out Timer shuts off the CAT data input after the continuous transmission of
the programmed time.
029 GEnE CAT RTS
Function: Enables/Disables the RTS port of the CAT jack.
Available Values: On/OFF
Default Setting: OFF
030 GEnE MEM GRP
Function: Enables/Disables Memory Group Operation.
Available Values: On/OFF
Default Setting: OFF
031 GEnE Q SPLIT
Function: Selects the tuning offset for the Quick Split feature.
Available Values: –20 ~ 0 ~ +20 kHz (1 kHz Step)
Default Setting: +5 kHz
032 GEnE TX TOT
Function: Sets the Time-Out Timer countdown time.
Available Values: OFF/5/10/15/20/25/30 min
Default Setting: OFF
The Time-Out Timer shuts off the transmitter after continuous transmission of the
programmed time.
033 GEnE TRV SET
Function: Set the 10’s and 1’s of the MHz digits display for operation with a
transverter.
Available Values: 30 ~ 49 MHz
Default Setting: 44 MHz
If you connect a 430 MHz transverter to the radio, set this menu to “30” (the “100
MHz” digits are hidden on this radio).
034 GEnE µT DIAL
Function: Select the µ-TUNE mode.
Available Values: StP1/ StP2/OFF