background image

20304166

VCFDVI31 Gas Fireplace Insert

47

lIMIteD 10 yeAR WARRANty

limited 10 year warranty

The following components are warranted for 10 years from the date of purchase of the product: Firebox, 

Combustion Chamber, Heat Exchanger, Grate, Stainless Steel Burners, Glass (thermal breakage only), 

Ceramic  Fiber  Logs  and  Refractory  Brick.  Coverage  is  provided  only  to  the  original  purchaser  and  is 

nontransferable. MHSC will also pay for reasonable labor costs associated with repairing or replacing the 

component described above for up to three (3) years. Labor rates will be determined by MHSC’s published 

labor rates in effect at the time labor is performed. 

Basic warranty

MHSC warrants the components and materials in your gas appliance to be free from manufacturing and 

material defects for a period of two (2) years from date of installation. After installation, if any of the compo-

nents manufactured by MHSC in the appliance are found to be defective in materials or workmanship, MHSC 

will, at its option, replace or repair the defective components at no charge to the original owner. MHSC will 

also pay for reasonable labor costs incurred in replacing or repairing such components for a period of two 

(2) years from date of installation. Any products presented for warranty repair must be accompanied by a 

dated proof of purchase.
This limited 10 year warranty will be void if the appliance is not installed by a qualified installer in accor-

dance with the installation instructions. The limited 10 year warranty will also be void if the appliance is not 

operated and maintained according to the operating instructions supplied with the appliance, and does not 

extend to (1) firebox/burner assembly damage by accident, neglect, misuse, abuse, alterations, negligence 

of others, including the installation thereof by unqualified installers, (2) the costs of removal, reinstallation 

or transportation of defective parts on the appliance, or (3) incidental or consequential damage. All service 

work must be performed by a Monessen authorized dealer.
This warranty is expressly in lieu of other warranties, expressed or implied, including the warranty of mer-

chantability of fitness for purpose and of all other obligations or liabilities. MHSC does not assume for it 

any other obligations or liabilities in connection with sale or use of the appliance. In states that do not allow 

limitations on how long an implied warranty lasts, or do not allow exclusion of indirect damage, those limita-

tions or exclusions may not apply to you. You may also have additional rights not covered in the limited 10 

year warranty.
MHSC reserves the right to investigate any and all the claims against the limited 10 year warranty and decide 

upon method of settlement.

If warranty service is needed...

1.  Contact your supplier. Make sure you have your warranty, your sales receipt and the model/serial 

number of your MHSC product.

2.  Do not attempt to do any service work yourself.

Содержание VCFDVI31

Страница 1: ...lt a qualified installer service agency or the gas supplier This appliance may be installed in an aftermarket permanently located manufactured home USA only or mobile home where not prohibited by loca...

Страница 2: ...Installation Items Needed 19 Check Gas Pressure 21 Gas Shutoff Tool 21 Electrical Installation 22 Electrical Wiring 22 Log Placement 23 Operating Instructions 26 For Your Safety Read Before Lighting...

Страница 3: ...d by a qualified service person with glass door properly seated and sealed combustion leakage can occur CARBON MONOXIDE POISONING Early signs of carbon monoxide poisoning are similar to the flu with h...

Страница 4: ...pliances have been tested by CSA and found to comply with the established standards for DIRECT VENT GAS FIREPLACE HEATERS in the USA and Canada as follows LISTED VENTED GAS FIREPLACE HEATER TESTED TO...

Страница 5: ...tings are shown in BTU per hour and are certified without deration for elevations up to 4 500 feet 1 370 m above sea level For elevations above 4 500 feet 1 370 m in USA installation must be in accord...

Страница 6: ...lace Insert 2256QE 560 mm 115 6QE 303 mm 1056 257 mm 2 6QE 56 mm 55 6QE 144 mm 1656 410 mm 24 6QE 621 mm 2756 689 mm 256M 57 mm 2156QE 535 mm 4164 ICFDV insert dims insert dimensions Figure 2 VCFDVI31...

Страница 7: ...cific installation requirements IMPORTANT Your direct vent insert was designed to be installed in an existing wood burning fireplace The location and clearances are subject to local building codes INS...

Страница 8: ...m from the fireplace opening local codes may require a larger hearth The hearth must also extend to both sides of the face FP2959 Figure 3 Mantel Clearances NOTE Side clearance to combustibles is 10 2...

Страница 9: ...DIMS 22 6 568 mm 20 6M 527 mm 16 6M 426 mm 30 6M 781 mm 29N m 759 mm with control box and bracket removed REMOVE COMMAND CENTER BRACKET In order to fit insert into a smaller opening the command center...

Страница 10: ...s well ventilated OPEN ALL WINDOWS DURING INITIAL BURN OFF CURING PHASE Burn your insert for at least six 6 hours on HIGH the first time you use it Place the fan in the OFF position during this time P...

Страница 11: ...g installation Failure to do so could result in serious injury property damage or loss of life Operation of improperly installed and maintained venting system could result in serious injury property d...

Страница 12: ...resize orifice for use at high altitude contact your dealer High Temp Silicone FP2948 exhaust pipe 3 and 3 UL 1777 Gas Liner Apply high temperature silicone to lines on both ends and secure with two 2...

Страница 13: ...ommended block off plate noncombustible metal Prevents odors from chimney entering room UL 127 Solid Fuel Z C Fire box Figure 11 Inlet and Exhaust Reline NOTE You may use either reline configuration w...

Страница 14: ...replace screw 3 Use the large end of the tool to unlatch the two 2 glass frame latches 4 Pull glass frame away from unit and lift up and away WARNING HOT GLASS WILL CAUSE BURNS DO NOT TOUCH GLASS UNTI...

Страница 15: ...nnecting six pin connector Set aside Figure 14 FP2969 6pin connector Six Pin Connector FP2969 Figure 14 Disconnect Command Center Cable 4 Carefully insert engine in large opening on inside of firebox...

Страница 16: ...e corner of insert Insert plug end of electric cord through hole in insert and through plastic grommet Slide grommet down electrical cord and reinstall Figure 19 FP2974 grommet Plastic Grommet FP2974...

Страница 17: ...1 front brick retainer bracket on each side with the screws removed in Step 2 4 Carefully set rear brick panel with notch up on log sup port 5 Carefully place right or left side brick panel in place...

Страница 18: ...screws Align slots in baffle plates so the slots are closed Retighten screws NOTE For propane LP units the baffle assembly is com pletely removed for venting under 20 ft 6 m For venting 20 ft and abov...

Страница 19: ...u must reduce incoming gas pressure to between 11 and 13 inches of wa ter If you do not reduce incoming gas pressure burner system regulator damage could occur Install external regulator with the vent...

Страница 20: ...aminants This keeps them from going into the burner system gas controls If sediment trap drip leg is not installed or is installed wrong burner system may not run properly NOTE The gas line connection...

Страница 21: ...and soap solution or a gas sniffer 4 To check gas pressures at valve turn captured screw counter clockwise 2 or 3 turns and then place tubing to pressure gauge over test point Turn unit to high Figur...

Страница 22: ...rical supply Electricity is only needed to operate blower Verify proper operation after servicing Electrical connections should only be performed by a qualified licensed electrician Main power must be...

Страница 23: ...nts such as pine cones or vermiculite to the heater Only use the logs supplied with the unit Failure to position the parts in accordance with diagrams below or to use only parts specifically approved...

Страница 24: ...n the right grate tine by placing the notch on the bottom of the log on the rear portion of the grate tine Figure 33 Log 3 LG1125 Figure 34 Log 4 LG1126 Figure 35 5 Install log 3 onto log 2 by placing...

Страница 25: ...h on the bottom of the right side onto the middle or remaining rectangular protrusion on log 2 Figure 36 LG1128 CFDVI log 6 7 Log 6 LG1128 Figure 37 Log 7 8 Install log 6 by placing rectangular notch...

Страница 26: ...Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department C Use only your finger to push in the master switch Never use tools If the switch will not func ti...

Страница 27: ...s go to next step 4 Press the master switch to the ON position Within eight 8 seconds it will beep once This indicates the system is ready 5 Press ON button Sparker will spark and pilot flame will lig...

Страница 28: ...brick panels 2 Remove log support bracket by removing two 2 screws in rear and one 1 screw on each side wall 3 Remove four 4 screws holding burner in place and slide burner to the left and up and out...

Страница 29: ...The slide adjustable air shutter has a range of 1 Figure 40 To increase air mixture open the slide adjustment by gently pulling on the lever When lever stops it has reached its maximum adjustment This...

Страница 30: ...battery Indication for Transmitter X Child Proof Lock out X LCD Backlight X Security Codes 16 X Countdown 6 hr Timer X Standard Thermostatic Control Mode X Smart Mode Thermostat Auto Flame Blower Mod...

Страница 31: ...ess button One beep for RF receiver ON or two beeps for RF receiver OFF will be given as confirmation Refer to Figure 41 for location 2 After the RF receiver is on holding the OFF button on the Comman...

Страница 32: ...um Low then Off 3 Hold the OFF button anytime for three seconds or by turning off the wall switch These two commands of OFF are Memory Off the system will remember all last settings before turning off...

Страница 33: ...ows The blue LED backlight lights up for 8 seconds when any of the touch buttons is pressed The menus include TIMER THERMO LIGHT FAN and AUX Rear Burner Control The adjustment arrows include ON up and...

Страница 34: ...mmand Cen ter will flash for 10 seconds 4 During the 10 sec onds press the OFF button on the transmitter to learn Another two beeps will be given to confirm a success ful learning Figure 46 TOUCH SCRE...

Страница 35: ...lace will be shut down completely when the timer counts down to zero 6 To exit Timer Mode a Push and hold the TIMER button for 3 seconds Or b Use the OFF down buttons to decrease the Set Time to zero...

Страница 36: ...down button to increase de crease the blower speed 3 Press the fan button again to confirm the speed set ting If the fireplace is on the blower speed will take effect right away if the fireplace is o...

Страница 37: ...A touch any place in the touch area to bring up the icons then press TIMER but ton and THERMO button at the same time for 3 sec onds The backlight will flash once to indicate that the setting has cha...

Страница 38: ...is blank 2 Check battery installation or replace batteries 3 LCD display shows funny display 3 Reset the transmitter see Resetting the Transmitter section 4 Appliance does not come on 2 The transmitte...

Страница 39: ...t and lint to the surface of the glass The initial paint curing of the appliance can also leave a slight film on the glass This is a temporary problem You should clean the glass after the first two we...

Страница 40: ...main burner and pilot 5 Carefully replace log set and embers in their correct positions Refer to Pages 23 through 25 6 Replace door 7 Relight pilot Refer to Page 27 8 Turn on main burners Allow logs t...

Страница 41: ...is found heater must be adjusted Contact dealer where you bought heater 4 Remove rock wool Clean burner and burner ports Figure 59 5 Replace log set and rock wool according to instructions on Pages 23...

Страница 42: ...ugh Battery polarity wrong LED on the Command Center does not show solid green The 5 pin connector on the AC board broken or bent AC plug is plugged to AC mains Battery voltage low Using battery Check...

Страница 43: ...20304166 VCFDVI31 Gas Fireplace Insert 43 REPLACEMENT PARTS 24 6 1 2 3 4 5 8 11 12 14 16 39 32 34 33 38 4166 VCFDVI31 parts 10 17 27 25 26 31 30 29 7 9 13 15 18 19 20 21 22 11 19 23 40...

Страница 44: ...Flex Line w Mounting Plate 1 20303795 20303795 25 Control Board NG SCS 1 80D0018 80D0018 26 Command Center SCS 1 80D0005 80D0005 27 AC Module SCS 1 80D0004 80D0004 28 Remote Control 1 TSFSC TSFSC 29...

Страница 45: ...5b Glass Frame Textured Mocha ICF30GTTM 6a Rectangular Double Door Satin Black ICF30R2DSB 6b Rectangular Double Door Vintage Iron ICF30R2DVI 6c Rectangular Double Door Textured Mocha ICF30R2DTM 7a Arc...

Страница 46: ...ly with the above requirements provided however that during said thirty 30 day period a battery operated carbon monoxide detector with an alarm shall be installed Massachusetts Residents Only Please r...

Страница 47: ...d if the appliance is not installed by a qualified installer in accor dance with the installation instructions The limited 10 year warranty will also be void if the appliance is not operated and maint...

Страница 48: ...s Fireplace Insert MHSC 149 Cleveland Drive Paris Kentucky 40361 www mhsc com Efficiency Ratings Model EnerGuide Ratings D O E Fireplace Efficiency AFUE VCFDVI31LENTSC 69 0 68 0 VCFDVI31LENTSC 72 9 70...