background image

36

20304166

VCFDVI31 Gas Fireplace Insert

tOuCh sCReeN ReMOte CONtROl OpeRAtION

the flame height according to the difference between the 

Set temperature and the Room temperature. There is no 

manual flame height adjustment. The fan speed will also 

automatically adjust if turned on.

NOte:

 When entering the Smart Mode

®

 thermostat func-

tion  there  will  be  a  10  second  delay  for  the  flame  and 

blower adjustment. When Smart Mode

®

 thermostat oper-

ates automatically there can be up to a 3 minute delay for 

flame/blower adjustment. Smart Mode

®

 thermostat checks 

temperatures every 3 minutes. Also see AUX Control.
1.  When Set Temp. is 3° F or higher than Room Temp., 

flame height will be on High.

2.  When  Set  Temp.  is  2°  F  higher  than  Room  Temp., 

flame height will be on Medium.

3.  When  Set  Temp.  is  1°  F  higher  than  Room  Temp., 

flame height will be on Low.

4.  When Set Temp. is equal to Room Temp., flame height 

does not change (stays on low).

5.  When Set Temp. is lower than Room Temp., the fire-

place will be shut off.

6.  When  Set  Temp.  is    1°  F  higher  than  Room  Temp., 

again the flame height will be on Low.

7.  the  fan  speed  follows  the  flame  height,  if  the  fan  is 

turned on.

To  exit  Smart  Mode

®

  thermostat  and  shut  off  the  fire-

place;
  a. push and hold the THERMO buttons for 3 sec-

onds, Or

  b. press the OFF button, Or

  c. slide down on the arrow buttons.

To shut off the Smart Mode

®

 thermostat option and return 

to regular thermostat mode, press and hold the THERMO 

button and the ON/UP button at the same time for 3 sec-

onds again.

Blower speed Control

Figure 51

NOte:

 Blower will only work with 

flame on.
The blower speed control function 

is used to adjust the speed of the 

blower connected to the Signature 

Command System. There are four 

speed  levels,  Off,  Low,  Medium, 

High.
1.  Press the FAN button to enter 

the blower speed control mode. 

The fan icon will start flashing.

2.  Press the ON/up and OFF/down button to increase/de-

crease the blower speed.

3.  Press the fan button again to confirm the speed set-

ting. If the fireplace is on, the blower speed will take 

effect right away; if the fireplace is off, the receiver will 

remember this setting and the blower is still off (see 

blower On Delay and Off Delay in the next section).

4.  After the signal is sent, the ON/up and OFF/down but-

tons become flame height controller again.

5.  When the fan button is flashing, slide up and down on 

the arrow buttons will turn the blower speed to High 

or Off directly without pressing the fan button again to 

confirm.

6.  If the blower  is turned on using  the FAN button, the 

blower  speed  will  adjust  automatically  when  using 

Smart Mode (See Smart Mode section).

Blower On Delay time and Off Delay time setup

Figure 52

1.  Hold the FAN button for 3 sec-

onds  until  two  numbers  ap-

pear  on  the  LCD  screen.  The 

left number is blower On Delay 

and the right number is blower 

Off Delay Time.

2.  When the first number is flash-

ing,  use  the  ON/up  button  to 

set the desired On Delay Time 

from 0 to 15 min.

3.  Press  the  OFF/down  button 

to jump to the Off Delay Time 

setup.

4.  When  the  second  number  is 

flashing, use the ON/up button again to set the desired 

Off Delay Time from 0 to 15 min.

5.  Press the OFF/down button again to finish the setup 

and the new settings will be transmitted to the receiv-

er.

6.  The  default  settings  are  5  minutes  for  the  On  Delay 

Time and 8 minutes for the Off Delay Time, as shown.

light Brightness Control

Figure 53

The light brightness control func-

tion is used to adjust the bright-

ness of the light bulbs connected 

to the AC module on the Signa-

ture  Command  System.  There 

are  four  light  brightness  levels 

defined: Off, Low, Medium, High
1.  Press the LIGHT button to en-

ter the light brightness control 

mode.  The  LIGHT  icon  will 

start flashing.

2.  Press  the  On/up  and  OFF/

down buttons to increase/de-

crease  the  light  brightness 

(Off-Low-Medium-High).

FP2656
blower delay setup

FP2657
Light bright control

Figure 53

Figure 52

FP2655
blower speed control

Figure 51

Содержание VCFDVI31

Страница 1: ...lt a qualified installer service agency or the gas supplier This appliance may be installed in an aftermarket permanently located manufactured home USA only or mobile home where not prohibited by loca...

Страница 2: ...Installation Items Needed 19 Check Gas Pressure 21 Gas Shutoff Tool 21 Electrical Installation 22 Electrical Wiring 22 Log Placement 23 Operating Instructions 26 For Your Safety Read Before Lighting...

Страница 3: ...d by a qualified service person with glass door properly seated and sealed combustion leakage can occur CARBON MONOXIDE POISONING Early signs of carbon monoxide poisoning are similar to the flu with h...

Страница 4: ...pliances have been tested by CSA and found to comply with the established standards for DIRECT VENT GAS FIREPLACE HEATERS in the USA and Canada as follows LISTED VENTED GAS FIREPLACE HEATER TESTED TO...

Страница 5: ...tings are shown in BTU per hour and are certified without deration for elevations up to 4 500 feet 1 370 m above sea level For elevations above 4 500 feet 1 370 m in USA installation must be in accord...

Страница 6: ...lace Insert 2256QE 560 mm 115 6QE 303 mm 1056 257 mm 2 6QE 56 mm 55 6QE 144 mm 1656 410 mm 24 6QE 621 mm 2756 689 mm 256M 57 mm 2156QE 535 mm 4164 ICFDV insert dims insert dimensions Figure 2 VCFDVI31...

Страница 7: ...cific installation requirements IMPORTANT Your direct vent insert was designed to be installed in an existing wood burning fireplace The location and clearances are subject to local building codes INS...

Страница 8: ...m from the fireplace opening local codes may require a larger hearth The hearth must also extend to both sides of the face FP2959 Figure 3 Mantel Clearances NOTE Side clearance to combustibles is 10 2...

Страница 9: ...DIMS 22 6 568 mm 20 6M 527 mm 16 6M 426 mm 30 6M 781 mm 29N m 759 mm with control box and bracket removed REMOVE COMMAND CENTER BRACKET In order to fit insert into a smaller opening the command center...

Страница 10: ...s well ventilated OPEN ALL WINDOWS DURING INITIAL BURN OFF CURING PHASE Burn your insert for at least six 6 hours on HIGH the first time you use it Place the fan in the OFF position during this time P...

Страница 11: ...g installation Failure to do so could result in serious injury property damage or loss of life Operation of improperly installed and maintained venting system could result in serious injury property d...

Страница 12: ...resize orifice for use at high altitude contact your dealer High Temp Silicone FP2948 exhaust pipe 3 and 3 UL 1777 Gas Liner Apply high temperature silicone to lines on both ends and secure with two 2...

Страница 13: ...ommended block off plate noncombustible metal Prevents odors from chimney entering room UL 127 Solid Fuel Z C Fire box Figure 11 Inlet and Exhaust Reline NOTE You may use either reline configuration w...

Страница 14: ...replace screw 3 Use the large end of the tool to unlatch the two 2 glass frame latches 4 Pull glass frame away from unit and lift up and away WARNING HOT GLASS WILL CAUSE BURNS DO NOT TOUCH GLASS UNTI...

Страница 15: ...nnecting six pin connector Set aside Figure 14 FP2969 6pin connector Six Pin Connector FP2969 Figure 14 Disconnect Command Center Cable 4 Carefully insert engine in large opening on inside of firebox...

Страница 16: ...e corner of insert Insert plug end of electric cord through hole in insert and through plastic grommet Slide grommet down electrical cord and reinstall Figure 19 FP2974 grommet Plastic Grommet FP2974...

Страница 17: ...1 front brick retainer bracket on each side with the screws removed in Step 2 4 Carefully set rear brick panel with notch up on log sup port 5 Carefully place right or left side brick panel in place...

Страница 18: ...screws Align slots in baffle plates so the slots are closed Retighten screws NOTE For propane LP units the baffle assembly is com pletely removed for venting under 20 ft 6 m For venting 20 ft and abov...

Страница 19: ...u must reduce incoming gas pressure to between 11 and 13 inches of wa ter If you do not reduce incoming gas pressure burner system regulator damage could occur Install external regulator with the vent...

Страница 20: ...aminants This keeps them from going into the burner system gas controls If sediment trap drip leg is not installed or is installed wrong burner system may not run properly NOTE The gas line connection...

Страница 21: ...and soap solution or a gas sniffer 4 To check gas pressures at valve turn captured screw counter clockwise 2 or 3 turns and then place tubing to pressure gauge over test point Turn unit to high Figur...

Страница 22: ...rical supply Electricity is only needed to operate blower Verify proper operation after servicing Electrical connections should only be performed by a qualified licensed electrician Main power must be...

Страница 23: ...nts such as pine cones or vermiculite to the heater Only use the logs supplied with the unit Failure to position the parts in accordance with diagrams below or to use only parts specifically approved...

Страница 24: ...n the right grate tine by placing the notch on the bottom of the log on the rear portion of the grate tine Figure 33 Log 3 LG1125 Figure 34 Log 4 LG1126 Figure 35 5 Install log 3 onto log 2 by placing...

Страница 25: ...h on the bottom of the right side onto the middle or remaining rectangular protrusion on log 2 Figure 36 LG1128 CFDVI log 6 7 Log 6 LG1128 Figure 37 Log 7 8 Install log 6 by placing rectangular notch...

Страница 26: ...Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department C Use only your finger to push in the master switch Never use tools If the switch will not func ti...

Страница 27: ...s go to next step 4 Press the master switch to the ON position Within eight 8 seconds it will beep once This indicates the system is ready 5 Press ON button Sparker will spark and pilot flame will lig...

Страница 28: ...brick panels 2 Remove log support bracket by removing two 2 screws in rear and one 1 screw on each side wall 3 Remove four 4 screws holding burner in place and slide burner to the left and up and out...

Страница 29: ...The slide adjustable air shutter has a range of 1 Figure 40 To increase air mixture open the slide adjustment by gently pulling on the lever When lever stops it has reached its maximum adjustment This...

Страница 30: ...battery Indication for Transmitter X Child Proof Lock out X LCD Backlight X Security Codes 16 X Countdown 6 hr Timer X Standard Thermostatic Control Mode X Smart Mode Thermostat Auto Flame Blower Mod...

Страница 31: ...ess button One beep for RF receiver ON or two beeps for RF receiver OFF will be given as confirmation Refer to Figure 41 for location 2 After the RF receiver is on holding the OFF button on the Comman...

Страница 32: ...um Low then Off 3 Hold the OFF button anytime for three seconds or by turning off the wall switch These two commands of OFF are Memory Off the system will remember all last settings before turning off...

Страница 33: ...ows The blue LED backlight lights up for 8 seconds when any of the touch buttons is pressed The menus include TIMER THERMO LIGHT FAN and AUX Rear Burner Control The adjustment arrows include ON up and...

Страница 34: ...mmand Cen ter will flash for 10 seconds 4 During the 10 sec onds press the OFF button on the transmitter to learn Another two beeps will be given to confirm a success ful learning Figure 46 TOUCH SCRE...

Страница 35: ...lace will be shut down completely when the timer counts down to zero 6 To exit Timer Mode a Push and hold the TIMER button for 3 seconds Or b Use the OFF down buttons to decrease the Set Time to zero...

Страница 36: ...down button to increase de crease the blower speed 3 Press the fan button again to confirm the speed set ting If the fireplace is on the blower speed will take effect right away if the fireplace is o...

Страница 37: ...A touch any place in the touch area to bring up the icons then press TIMER but ton and THERMO button at the same time for 3 sec onds The backlight will flash once to indicate that the setting has cha...

Страница 38: ...is blank 2 Check battery installation or replace batteries 3 LCD display shows funny display 3 Reset the transmitter see Resetting the Transmitter section 4 Appliance does not come on 2 The transmitte...

Страница 39: ...t and lint to the surface of the glass The initial paint curing of the appliance can also leave a slight film on the glass This is a temporary problem You should clean the glass after the first two we...

Страница 40: ...main burner and pilot 5 Carefully replace log set and embers in their correct positions Refer to Pages 23 through 25 6 Replace door 7 Relight pilot Refer to Page 27 8 Turn on main burners Allow logs t...

Страница 41: ...is found heater must be adjusted Contact dealer where you bought heater 4 Remove rock wool Clean burner and burner ports Figure 59 5 Replace log set and rock wool according to instructions on Pages 23...

Страница 42: ...ugh Battery polarity wrong LED on the Command Center does not show solid green The 5 pin connector on the AC board broken or bent AC plug is plugged to AC mains Battery voltage low Using battery Check...

Страница 43: ...20304166 VCFDVI31 Gas Fireplace Insert 43 REPLACEMENT PARTS 24 6 1 2 3 4 5 8 11 12 14 16 39 32 34 33 38 4166 VCFDVI31 parts 10 17 27 25 26 31 30 29 7 9 13 15 18 19 20 21 22 11 19 23 40...

Страница 44: ...Flex Line w Mounting Plate 1 20303795 20303795 25 Control Board NG SCS 1 80D0018 80D0018 26 Command Center SCS 1 80D0005 80D0005 27 AC Module SCS 1 80D0004 80D0004 28 Remote Control 1 TSFSC TSFSC 29...

Страница 45: ...5b Glass Frame Textured Mocha ICF30GTTM 6a Rectangular Double Door Satin Black ICF30R2DSB 6b Rectangular Double Door Vintage Iron ICF30R2DVI 6c Rectangular Double Door Textured Mocha ICF30R2DTM 7a Arc...

Страница 46: ...ly with the above requirements provided however that during said thirty 30 day period a battery operated carbon monoxide detector with an alarm shall be installed Massachusetts Residents Only Please r...

Страница 47: ...d if the appliance is not installed by a qualified installer in accor dance with the installation instructions The limited 10 year warranty will also be void if the appliance is not operated and maint...

Страница 48: ...s Fireplace Insert MHSC 149 Cleveland Drive Paris Kentucky 40361 www mhsc com Efficiency Ratings Model EnerGuide Ratings D O E Fireplace Efficiency AFUE VCFDVI31LENTSC 69 0 68 0 VCFDVI31LENTSC 72 9 70...

Отзывы: