The manufacturer hereby warrants normal operation of the unit for 24 months after the retail sale date provided the user’s observance of the 

transportation, storage, mounting and operation regulations.

Should any malfunctions occur in the course of the unit operation through the Manufacturer’s fault during the guaranteed period of operation the user 

is entitled to elimination of faults by the manufacturer by means of warranty repair at the factory free of charge.

The warranty repair shall include work specifi c to elimination of faults in the unit operation to ensure its intended use by the user within the guaranteed 

period of operation.

The faults are eliminated by means of replacement or repair of the unit components or a specifi c part of such unit component.

The warranty repair does not include:

• 

routine technical maintenance

• 

unit installation/dismantling

• 

unit setup

To benefi t from warranty repair the user must provide the unit, the user’s manual with the purchase date stamp and the payment document certifying 

the purchase.

The unit model must comply with the one stated in the user’s manual. 

Contact the Seller for warranty service.

The manufacturer’s warranty does not apply to the following cases:

• 

User’s failure to submit the unit with the entire delivery package as stated in the user’s manual including submission with missing component parts 
previously dismounted by the user.

• 

Mismatch of the unit model and the brand name with the information stated on the unit packing and in the user’s manual.

• 

User’s failure to ensure timely technical maintenance of the unit.

• 

External damage to the unit casing (excluding external modifi cations as required for installation) and internal components caused by the user.

• 

Redesign or engineering changes to the unit.

• 

Replacement and use of any assemblies, parts and components not approved by the manufacturer.

• 

Unit misuse.

• 

User’s violation of the unit installation regulations.

• 

User’s violation of the unit control regulations.

• 

Unit connection to the power mains with a voltage diff erent from the one stated in the user’s manual.

• 

Unit breakdown due to voltage surges in the power mains.

• 

Discretionary repair of the unit by the user.

• 

Unit repair by any persons without the manufacturer’s authorization.

• 

Expiration of the unit warranty period.

• 

User’s violation of the unit transportation regulations.

• 

User’s violation of the unit storage regulations.

• 

Wrongful actions against the unit committed by third parties.

• 

Unit breakdown due to circumstances of insuperable force (fi re, fl ood, earthquake, war, hostilities of any kind, blockades).

• 

Missing seals if provided by the user’s manual.

• 

Failure to submit the user’s manual with the unit purchase date stamp.

• 

Missing payment document certifying the unit purchase.

MANUFACTURER’S WARRANTY

FOLLOWING THE REGULATIONS STIPULATED HEREIN WILL ENSURE A LONG 

AND TROUBLE-FREE OPERATION OF THE UNIT.

USERS’ WARRANTY CLAIMS SHALL BE SUBJECT TO REVIEW ONLY UPON PRESENTATION 

OF THE UNIT, THE PAYMENT DOCUMENT AND THE USER’S MANUAL WITH 

THE PURCHASE DATE STAMP.

Содержание VUTR 200 V2 EC A17

Страница 1: ...USER S MANUAL Heat recovery air handling unit VUTR 200 V2 EC A17 VUTR 200 V2 EC A18 VUTR 200 V2 E EC A17 VUTR 200 V2 E EC A18...

Страница 2: ...ion electrical and technical norms and standards The warnings contained in the user s manual must be considered most seriously since they contain vital personal safety information Failure to follow th...

Страница 3: ...t Disconnect the unit from power mains prior to any technical maintenance Do not store any explosive or highly ammable substances in close proximity to the unit When the unit generates unusual sounds...

Страница 4: ...MUST PREVENT UNAUTHORIZED ACCESS BY UNATTENDED CHILDREN The unit is designed for wall and oor mounting The unit is rated for continuous operation Transported air must not contain any ammable or explos...

Страница 5: ...Top view 135 347 510 600 598 125 95 139 113 95 144 124 141 TECHNICAL DATA Parameters VUTR 200 V2 A17 VUTR 200 V2 A18 VUTR 200 V2E EC A17 VUTR 200 V2E EC A18 Unit voltage V 50 60 Hz 1 230 Maximal unit...

Страница 6: ...hood The kitchen hood must be equipped with an air damper to shut o the exhaust duct when the kitchen hood is not in use UNIT DESIGN AND OPERATION PRINCIPLE SERVICE SIDE VIEW Intake filter Extract air...

Страница 7: ...short or not connected protect the unit parts from ingress of foreign objects To prevent uncontrollable access to the fans the spigots may be covered with a protecting grille or other protecting devi...

Страница 8: ...and install a humidity sensor into the mount on the extract air duct panel and then connect the humidity sensor contact socket to the respective contact socket on the control unit 1 2 3 Contact socke...

Страница 9: ...undo the four self tapping screws and remove the plug in the bottom panel Lead the kitchen hood cable into the unit and connect it according to the external connections wiring diagram page 12 Fix the...

Страница 10: ...ntrol panel 3 Complete the electrical connections according to the external wiring diagram Page 12 4 Secure the rear part of the control panel in the mounting box using the screws supplied 5 Connect t...

Страница 11: ...a wall route the phone cable to the selected location 1 Secure the rear part of the casing in the standard box by means of the round head screws supplied 2 Connect the phone cable to the front part of...

Страница 12: ...to the unit Connection to a re alarm panel and an enable signal of compressor condenser unit CCU operation are foreseen For accessing the terminal block and the controller undo the screws securing th...

Страница 13: ...t an outdoor air temperature sensor a supply air temperature sensor a temperature sensor of an exhaust duct a room temperature sensor when using the th Tune with the temperature sensor A17 a humidity...

Страница 14: ...s the knob to set the start time and the corresponding temperature setpoint for each time range individually you may create up to six time ranges The pictogram shows the current time of a day status i...

Страница 15: ...the display screen Simultaneously press the Up Down and Enter buttons and hold them for 3 5 seconds After this time the message Display address setting 32 appears on the display screen 3 Move the cur...

Страница 16: ...on for cancelling the parameter edits and exiting the submenu Parameters Prg Access to the additional options menu Alarms Access to the alarm view and reset menu THE SERVICE SETTINGS ARE PROGRAMMED AT...

Страница 17: ...t exchanger and the electric heater 3 Outside air temperature Readings are taken from the temperature sensor built into the supply duct upstream of the heat exchanger UNIT OPERATION MODE SELECTION The...

Страница 18: ...ty of each fan via the unit parameter setup menu UNIT PARAMETERS To enter the user parameter menu press the button Use and to select the desired menu item and press to enter 1 System information To vi...

Страница 19: ...t time scheduler The Set time scheduler menu consists of four pages To navigate between the pages use the and buttons Attention With the th Tune control panel connected the scheduled operation is set...

Страница 20: ...the week as follows 1 Use the button to set the cursor at Copy to 2 Use and to select a day of the week or all days 3 Press and select Yes using and 4 To con rm the copying operation press the button...

Страница 21: ...setting the next special day 5 Setting up other special days Other special days are set up similarly Setting up setpoints Page 4 4 The setpoints for schedule entries are programmed on page 4 4 Setting...

Страница 22: ...of the temperature regulator If the temperature regulator type value is 1 temperature is controlled by room temperature If the temperature regulator type value is 1 the temperature is controlled by r...

Страница 23: ...active alarms can be reset manually To reset an alarm manually press in the active alarms menu and enter the alarm control menu The alarm management menu enables the following actions viewing the curr...

Страница 24: ...aning is required To clean the heat exchanger remove it from the unit and clean the heat exchanger by using compressed air or a vacuum cleaner After cleaning re install the heat exchanger into the uni...

Страница 25: ...duct pipe anges Install anti vibration connectors SYSTEM ALARMS Fire alarm Emergency system shutdown on command from the re alarm board This alarm interrupts the fan operation In case of such alarm f...

Страница 26: ...he user Mismatch of the unit model and the brand name with the information stated on the unit packing and in the user s manual User s failure to ensure timely technical maintenance of the unit Externa...

Страница 27: ...umber E mail Purchase Date Seller s Stamp Seller s Stamp Installation Company Stamp This is to certify acceptance of the complete unit delivery with the user s manual The warranty terms are acknowledg...

Страница 28: ...V140 1EN 01...

Отзывы: