To modify the unit operation parameters move the cursor to the required line using the
button. Then use
and
to set the desired value and then
press
to confi rm. To exit the parameter change mode without saving the changes press
.
VIEWING TEMPERATURE SENSOR READINGS
To view the readings from the temperature sensors installed in the unit move the cursor to the upper left corner by means of the
button and then
use
and
to select the necessary sensor for viewing.
1. Room temperature. Readings are taken from the temperature sensor
built into the control panel or the exhaust duct temperature sensor.
2. Supply air temperature. Readings are taken from the temperature
sensor built into the supply duct downstream of the heat exchanger and
the electric heater.
3. Outside air temperature. Readings are taken from the temperature
sensor built into the supply duct upstream of the heat exchanger.
UNIT OPERATION MODE SELECTION
The unit has 4 operation modes. To select the desired mode place the cursor on the «Mode» word using the
button. Then use
and
to set the desired value and then press
to confi rm.
1.
OFF
— the fans and the heat exchanger are disabled. Temperature and
speed settings are not available.
2.
FAN
— the fans run at the pre-selected speed. The heat exchanger
and the electric heater are disabled. The temperature settings are not
available. This mode can be enabled only from the pGD1 control panel.
3.
Auto
mode — the fans, the heat exchanger and the electric heater
are enabled. The user may change the temperature and speed settings.
4.
Scheduler
— the fans, the heat exchanger and the electric heater
are enabled. Temperature and speed settings are available in the
«Scheduler».