BTRM Battery Test Remote Monitoring System – User Guide V3.2 |
ã
2021 Ventev | LIT SKU: 09834
43
The Router is the message destination. The Router looks at the message’s port, checks its
port forwarding table to see if the UDP port 162 is forwarded to a local LAN IP address. If so,
delivers it to that IP address (in this case the Host Computer), otherwise the message is
discarded.
14.3
Port Table
Function
Default Port Values
TCP/IP
UDP
Web Page Access (http)
80
SNMP Management Access
161
SNMP Notifications
162
1
DNP3
1
20000
Modbus
1
502
Firmware Update
16384
(1) Port is user selectable
15. Specifications and Warranty
Electrical Specifications
BTRM300
BTRM400
Operating Voltage
9 to 30 VDC
9 to 60 VDC
Battery Max Current
20A
10 A
Continuous
Charger Max Current
20A
10 A
Continuous
Load Max Current
20A
10 A
Continuous
Battery and Charger
Voltage Measurement
0 to 60V ± 1%
Current Measurement
0 to 20 Amps ± 1%
Environmental
Temperature
-20° C to +60° C
Humidity
5 % to 95% Non-Condensing
Mechanical
Size
6.25” H X 2.8” D X 1.2” W
Weight
5.0 oz (142 g)
Mounting
Spring-Loaded Din rail mounting clip
Warranty
One Year Repair or Replace
No Warranty on systems deemed to have reversed wiring or over current
Note:
Specifications subject to change without notice.