Instruction Manual
VLB-92 Omni Mega LED Beacon
© Sabik Oy, Dec 2018
VLB-92 Omni Mega LED Beacon
Page 23 of 56
VLB-92 V1.19
APPENDIX A
PROGRAMMING TABLE
Operation
Feature
Value
1 =
Program
Mode
9 = Read
Settings
0 = Flash Character
000
– Fixed character
1YY
– Iso phase (ISO)
2YY
– Occulting (OC)
3YY
– Flash (Fl)
4YY - Multiple Flash (Fl(x))
5YY - Very Quick (VQ)
6YY - Quick (Q)
7YY
– Long (LF)
8YY
– Morse (MO)
9YY
– Custom (CCG Codes)
1 = Night Effective
Intensity
Four Digit Value
– Enter value as a number 0000 to 9999.
0000 Sets to minimum programmable intensity.
0001 Set to factory preset intensity.
9999 sets maximum allowed value.
Automatic Schmidt Clausen correction
2 = Day Effective
Intensity
Four Digit Value
– Enter value as a number 0000 to 9999.
0000 Sets to minimum programmable intensity.
0001 Set to factory preset intensity.
9999 sets maximum allowed value.
Automatic Schmidt Clausen correction
3 = Synchronisation
999
– Disable Synchronisation
998
– Beacon activated by holding sync low.
Synchronization not possible since sync line used.
0YY Light in normal mode
1YY Light operates only when sync pulse present
YY=sync delay seconds (0.0 to 9.9 seconds)
4 = Day/Night Control
0YY Light operates night only
1YY Light operates day and night
YY= Day/Night transition Lux Level
Night Lux. Day Lux
YY=01 40 100 shortest night
YY=02 50 150
YY=03 75 100 CCG
YY=04 75 150
YY=05 75 175 IALA suggested
YY=06 100 175
YY=07 100 200
YY=08 150 250
YY=09 250 320 longest night USCG