Instruction Manual
VLB-92 Omni Mega LED Beacon
© Sabik Oy, Dec 2018
VLB-92 Omni Mega LED Beacon
Page 16 of 56
VLB-92 V1.19
Exiting Programming mode
No programming activity for 10 Seconds
The light will give two quick flashes followed by
a short pause followed by another two quick
flashes.
After this it will resume normal operation. The
light will flash its character for 16 seconds
while it checks the day/night settings. If it is
daytime and the light is set to operate at night
only the light will turn off.
5.4.1 The Omni Mega Will Not Enter Programming Mode
If you find the beacon will not enter the programming mode it will be caused by one of 2 reasons:
•
The battery in the TVIR Programmer is missing, or the plastic battery insulator has not been
removed, or the battery has low voltage.
•
There is no power supply connected to the light or it is out of the specified voltage range.
If the beacon enters programming mode but rejects all commands then it requires a security PIN to
be entered by the operator to allow programming. Refer clause 5.5.10.
5.4.2 Becoming Familiar with the Syntax and Flash Feedback
If you have not used the Vega TVIR Programmer before, spend some time learning how the light
will respond to the various programming actions. Make sure the Omni Mega is connected to an
appropriate power supply voltage with sufficient current capacity and experiment with the following.
Enter and Exit Program mode
1. Enter program mode
Press the red standby button for 5 seconds
The light will give 4 quick flashes to indicate it has
entered programming mode
2. Exit program mode
Leave the programmer idle for 10 seconds
The light will give two quick flashes followed by a short
pause followed by another two quick flashes.
After this it will resume normal operation. The light will
flash its character for 16 seconds while it checks the
day/night settings. If it is daytime and the light is set to
operate at night only the light will turn off.
Program a Flash Character
with a flash character of Fl 10sec(1sec “on” 9sec “off”)
To program this Flash Character find the three-
digit code from Appendix K, “Flash character table
with program codes”. (Flash 10sec = code 350). Determine the programming Syntax from
Appendix A for the setting:
Operation
=Programming
=1
Feature
=Flash Character
=0
Value
=Code
=350
The programming sequence to enter this flash character is 10350
0. Enter programming mode
Press the red standby button for 5 seconds
The light will give 4 quick flashes to indicate it has
entered programming mode
2. Enter the programming sequence for the flash
character (10350)
The light will flash once each time a key on the
programmer is operated.
When the sequence is completed and accepted the
light will repeat the value 350 in a series of flashes.
Three quick flashes followed by a 0.5sec gap followed
by five quick flashes followed by a 0.5 second gap
followed by a 2 second flash (for a zero)
1. Exit programming mode
Leave the programmer idle for 10 seconds
The light will give two quick flashes followed by a short
pause followed by another two quick flashes.