Instruction Manual
VLB-92 Omni Mega LED Beacon
© Sabik Oy, Dec 2018
VLB-92 Omni Mega LED Beacon
Page 25 of 56
VLB-92 V1.19
2
–
Custom
Character
Setting
Custom flash character
segments
Up to 9 On/Off pairs. Comma Separated, 50 millisecond
units. Numbers 002 to 255 are permitted in the On/Off
pairs. 001 is a special case indicating continuation
(connect the two values on either side of 001)
002 to 255: 100 milliseconds to 12.75 seconds
001 - Extend an on or off period).
000
– End command
Examples:
a: 010 020 015 020 200 001 200 020 000
b: 006 012 006 012 000
c: 125 125 000
Illegal:
a: 020 001 001 020 000 (repeated connecting character)
b: 010 020 015 000 ( no off period after 015)
c: 020 010 020 010 ( no terminating 000 )
Operation
Feature
Value
3
– System
Information
0 = Software version
Version Y.Y.Y (i.e. 0.2.8)
1
– Battery voltage
YY.Y Volts (e.g. 21.7 volts or 10.8 volts) Last voltage
prior to entering programming mode
2
– Master Temp sensor
reading
Temperature in degrees Kelvin (C+273).
4
– Serial Number
Displays beacon serial number as a series of flashes
5
– LED version number
Displays LED version number identifier
Operation
Feature
Value
7 - Pin
1-Set PIN
Default 000
XXX (000 clears the PIN)
7
– Enter PIN
XXX
Operation
Feature
Value
8
– Other
Settings
1
– Reset Factory
Default
000
5 – Set RS232 Baud Rate
000 – Default (required for Vegaweb) – 115200 Baud
001 – 4800
002 – 9600
003 – 14400
004 – 19200
005 – 38400 (required for AIS)
006 – 57600
007 – 115200
6
– Indicator Select
Default 000
000
– Beacon main LEDs do not flash during
programming
001
– Beacon main LEDs flash in response to
programming